![RAB Lighting PIP XL 70W Installation Instructions Download Page 2](http://html1.mh-extra.com/html/rab-lighting/pip-xl-70w/pip-xl-70w_installation-instructions_3120107002.webp)
PIP XL 70W 100W INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
TM
RECEPTACLE OPTION
Units ordered with (/PCT) suffix is supplied with 3 wire
receptacle and 120-277V Twistlock Photocell. Units ordered
with (/PCT4) is supplied with 3 wire receptacle and 480V
Twistlock Photocell.
Units ordered with (/7PR) suffix is supplied with 7-Pin
receptacle without photocell. Brown and Orange wires from
the 7-Pin receptacle are not connected and are reserved to
DALI or other control systems.
BILEVEL DIMMER OPTION
For 100% light output (disabling the dimmer), splice red wire
with black line wire.
For chosen output only, leave red wire capped.
For Bilevel Function, connect red wire to switched device.
Determine what % light output is desired and set switch prior
to installation. Options are: 25%, 50%, and 75%.
WIRE GUARD INSTALLATION
Wire Guard mount with (4) #8-32
Stainless Steel Screws.
Screws are provided with the accessory. Line up guard with
existing pre-drilled holes in frame as shown, tighten screws.
Stainless Steel Screws (4)
HOOD INSTALLATION
Hood mount with (4) #8-32
Stainless Steel Screws.
Screws
are provided with the accessory. Line up hood with existing
pre-drilled holes in frame as shown, tighten screws.
Stainless Steel Screws (4)
ACCESSORIES
Wire Guard:
GDPIPXLW
12” Hood:
HPIPXL-12
Slipfitter Mount Replacement:
FFLEDXLSF
Trunnion Mount Replacement:
FFLEDXLT