background image

LFLED5MBR INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

 

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding 

is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A 

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.  

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

FIXTURE MOUNTING

THE FIXTURE IS MARINE LISTED, OUTSIDE TYPE (SALTWATER).

Mount to the supplied weatherproof junction box and cover 

plate as shown. To ensure weatherproof seal, apply weather 

proof silicone sealant around the edge of the wall coverplate 

or surface box. This is especially important with an uneven 

wall surface

1. 

Seal arm thread using teflon tape or silicone sealant. 

2. 

Thread fixture into 

Cover Plate

3. 

Connect wires as shown in the wiring diagram. 

4. 

Attach cover to 

Junction Box

5. 

Aim floodlight in the direction desired and tighten 

locknut and 

Arm Screw

.

Cover Plate

Junction Box

Note:  These instructions do not cover all details or variations in 

equipment nor do they provide for every possible situation during 

installation, operation or maintenance.

WIRING

Universal voltage driver permits operation at 120V thru 

240V, 50 or 60 Hz.

1. 

Connect the GROUND wire from fixture to supply 

ground.  

2. 

Connect the black fixture lead to the (+) LINE 

supply lead. 

3. 

Connect the white fixture lead to the (-) COMMON  

supply lead. 

Reviews: