background image

FLOODINATOR

TM

 INSTALLATION INSTRUCTIONS 

®

Page 2

REFLECTOR ADJUSTMENT

1. Loosen (4) door screws, open door.

2. Push each side of the refl ector at point shown 

below.  The Refl ector will lock in position.

3. For even distribution, each side of the refl ector 

should be adjusted to the same position.

4. Refl ectors are factory set at the widest beam, 

Position #1.

5. To move refl ector back in, gently lift up the refl ec-

tor piece with a fl at screwdriver. Bend refl ector 
back and place behind the 1st position stop.

Push Here

Position #2 
Shown

Hinge 

Hinge 

3 Position Stops

Middle Beam 

Adjustable Refl ector: Patent Pending

CLEANING & MAINTENANCE

CAUTION: Be sure fi xture temperature is cool 
enough to touch.  Do not clean or maintain while 
fi xture is energized.

1.  Clean glass lens with non-abrasive glass cleaning 

solution.

2.  As lamps age, light output diminishes.  Mass 

relamping at regular intervals ensures full light output 
at the highest effi ciency.

GUARD INSTALLATION

1. Mount GDFN Guard with (4) #10-24 x 3/8” screws as 

shown below.

2. Screws are provided with the Guard.

(4) Screws

HOOD INSTALLATION

1. Mount 6” Hood FNH6 or the 12” Hood FNH12

with (4) #10-24 x 3/8” screws as shown below.

2. Screws are provided with the Hood.

(4) Screws

GUARD & HOOD INSTALLATION

The wire guard and the 6” Hood FNH6 or the 12” Hood 
FNH12 can be mounted to the same fi xture
with (4) #10-24 x 3/8” screws as shown below.

Narrow Beam 

Wide Beam 

Position #1

Position #2

Position #3