TM

CAUTION

SILICONE ALL PLUGS AND UNUSED CONDUIT ENTRIES FOR WEATHER PROOF SEALING.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

 

Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required 

for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 

FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.  

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside

.

FOR AISLE FIXTURE

1.  Loosen the 

screw

 connecting 

Housing Head

 to Junction 

box.

2.  Rotate the 

Housing Head

 all the way as shown in Fig.1.

3.  Tighten the 

screw

.

FIXTURE MOUNTING 

Mount 

Housing

 to sturdy ceiling structure as follows:

FOR HOOK MOUNTING:

1. 

V Hooks (2)

 are provided for chain mounting. Secure               

V Hooks

 through 

Bracket Hole

 at back of 

Housing 

as in     

Fig. 2.

2.  Connect to two (2) equal lengths of chain (by others) and/

or appropriate hardware (by others) suitable for mounting 

surface, to suspend 

Housing 

from 

V Hooks. 

3.  Fixture mounting height and spacing should be determined 

by application requirements. Use chain suitable to support 

four (4) times the weight of the fixture (42 lbs).

4. 

Brackets (2)

 should be positioned near end of Housing as 

shown in Fig.2.

 

Secure 

Housing 

to ceiling mounting surface 

and adjust 

Brackets

 evenly to ensure 

Housing

 is stabilized.

5.  Unlatch and open the 

Wiring Box

 and slide 

Cord

 in  

Wiring Box

. Use approved wiring connectors and wire to 

local NEC codes.

FOR PENDANT/ SURFACE MOUNTING:

1.  Choose pendant length (3/4” NPS Pendant Stem not 

supplied) and feed

 Cord

 through pendant stems. If longer 

cord is required, replace the

 Cord

 with the appropriate length 

wires. For wet locations wrap threads on pendant stems with 

teflon tape and silicone gel. Screw the pendant stem to the 

Wiring Box

. Tighten set screw.

2.  Alternatively, mount 

Wiring Box

 to ceiling by drilling out drill 

locations. Use the appropriate  mounting hardware for the 

mounting surface. Be sure gasket is properly seated.

3.  Unlatch and open the 

Wiring Box

 and slide 

Cord

 in  

Wiring Box

. Use approved wiring connectors and wire to 

local NEC codes. 

V Hook

Wiring Box

Housing

Pendant

Fig: 1

Screw

Head in Aisle 

Position

Junction 

Box

FALCOR  

80W

FALCOR  

160W & 230W

FALCOR AISLE 

80W

FALCOR AISLE 

160W & 230W

Bracket

Bracket Hole

Fig: 2

Fig: 3

Summary of Contents for FALCOR 80W

Page 1: ...nnect to two 2 equal lengths of chain by others and or appropriate hardware by others suitable for mounting surface to suspend Housing from V Hooks 3 Fixture mounting height and spacing should be determined by application requirements Use chain suitable to support four 4 times the weight of the fixture 42 lbs 4 Brackets 2 should be positioned near end of Housing as shown in Fig 2 Secure Housing to...

Page 2: ... RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com ACCESSORIES Wire Guard GDFALCORW Poly Shield GDFALCORP GUARD OR SHIELD INSTALLATION Wire Guard and Poly Shield mount with 4 Stainless Steel Screws Screws are provided with the accessory See Fig 6 for Guard See Fig 7 for Shield 1 Line up guard or shield with existi...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...e NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Learn more at lightcloud com 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com WE RE HERE TO HELP ...

Page 22: ...ensor that can switch and dim both hardwired circuits and remote circuits using Lightcloud Controllers Hello Product Features Advanced PIR Sensing Secure Cloud Control Configuration Retrofit Friendly Local Control Scheduling Astronomical Clock Power Monitoring 0 10V Dimming Patent Pending Temperature Monitoring Light Sensor ...

Page 23: ...ALL DIMENSIONS 4 91 Diameter 1 61 Height WIRELESS RANGE Line of Sight 1000 feet Obstructions 100 feet Warranty is active as long as service plan is active Indoor Damp Location Lightcloud Ceiling Sensor or High Bay Sensor Instruction Manual Wire Nuts x 4 x 2 What You Need Lightcloud Gateway A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices Accessories For use...

Page 24: ...on may require additional Lightcloud devices to go around the obstruction LightcloudGateway 100 ft Add an additional Lightcloud Device to extend network range around corners BRICK CONCRETE OR METAL WALL DRY WALL OR SIMIL AR INSTALL AT A JUNCTION BOX INDOOR OUTDOOR The Sensor can control other Lightcloud devices wirelessly If you don t need to hard wire a switched circuit to the Sensor no problem j...

Page 25: ...LE GRAY PURPLE GRAY Setup Installation cont d This product should only be installed by a qualified electrician and in compliance with local and national electrical codes 3 Installing Accessories High Bay only Arm mount sensor to fixture using NPS threaded nipple Height Adjuster adjust height by loosening set screw moving sensor up or down along extruded tube then tightening set screw Ensure sensor...

Page 26: ...write in additional information such as Zone name Panel Circuit Number and whether or not a zone uses dimming ZONE NAME PANEL CIRCUIT Setup Installation cont d 6 7 Power up Confirm device connectivity Confirm status indicator LED see step 8 is solid green If it is not make sure your device is within range of another Lightcloud AC powered device To add new devices to your Lightcloud network contact...

Page 27: ...r by pushing up and twisting to the right clockwise STATUS INDICATOR 9 Commission Configure Your Devices All Lightcloud products can be commissioned and configured by Logging on to lightcloud com Calling RAB at 1 844 LIGHTCLOUD Emailing us at support lightcloud com ...

Page 28: ...CATOR After the Device Button has been pressed this indicator illuminates when the device receives a message and indicates the strength of the signal 3 Best Signal 2 Acceptable Signal 1 Unacceptable Signal Consult the Finding a Location section for more information DEVICE BUTTON Press once to highlight this device in the Lightcloud Application pressing once also enables display of the Signal Indic...

Page 29: ...ntrol other devices CONTROLLER MODE In Controller Mode the attached circuit is controllable as an independent zone in the Lightcloud application Motion detection and timeout can still be used via Lightcloud Automations to control other devices RANGE TEST MODE When Range Test Mode is activated via the Lightcloud application the timeout period is shortened so that you can test different sensitivitie...

Page 30: ... of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Note This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B of the FCC rules These limits are desig...

Page 31: ...Manual ...

Page 32: ...ement batteries CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO LOCAL LAWS Some communities offer recycling or collection of rechargeable batteries contact your local government for disposal practices in your area DISCONNECT An external readily accessible disconnect device such as a circuit breaker is required Custom manufactured in Chin...

Page 33: ...ateway Lightcloud Devices Finding a Suitable Location Best Practices Best Practices Getting Started Installation Lightcloud Gateway Lightcloud Devices Table Setup Network Setup Gateway Activation Lightcloud Devices 5 6 7 8 9 10 11 12 13 14 17 18 18 18 18 ...

Page 34: ...4 ...

Page 35: ... charge of your lighting from sensing to dimming schedules to scenes and everything in between Control and configure your system remotely using the Lightcloud Application or call RAB to have our experts set up your system just how you need it Welcome to lighting control that just works 5 ...

Page 36: ...etwork which allows site layout to be flexible and robust The Lightcloud Gateway and Devices require a subscription to function beyond the installation period Call RAB at 1 844 LIGHTCLOUD or visit lightcloud com to set up your account Your Lightcloud subscription gets you these state of the art features Online control configuration at control lightcloud com Device commissioning Free support Teleph...

Page 37: ...ur Lightcloud site is at your command with the Lightcloud Application For maximum security the Gateway isn t exposed to the internet at all and for maximum reliability the Gateway contains an Uninterruptible Power Supply UPS that will maintain power for up to 2 hours When the Gateway is not powered or available switching devices such as the Controller will fall back to a configurable emergency mod...

Page 38: ... sensor that measures available light and adjusts your lighting automatically Lightcloud Ceiling Sensor The Ceiling Sensor is an intelligent passive infrared motion sensor that can be configured for both occupancy and vacancy sensing Switches up to 15A and provides 0 10V dimming Lightcloud Dimmer The Wall Dimmer puts advanced control at your fingertip Configure via the Lightcloud App to switch dim...

Page 39: ...ines when installing additional Lightcloud devices If there is a clear line of sight between two devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep them within 100 feet of each other Brick concrete and steel construction may require additional devices to go around the obstruction ...

Page 40: ...tcloud Daylight devices do not extend the range of a Lightcloud network Lightcloud Gateway 100 ft Add an additional Lightcloud Device to extend network range around corners BRICK CONCRETE OR METAL WALL DRY WALL OR SIMIL AR M E TA L CO N C R E T E B R I C K PROBLEM MATERIALS Large amounts of metal concrete and brick are bad news for radio signals in some cases you ll have to go around these obstacl...

Page 41: ...M S A M P L I F I E R S A N T E N N A S PROBLEM DEVICES SIGNALS Lastly consider sources of invisible interference Avoid placing Lightcloud devices near microwaves motors especially elevator mechanical rooms or any other radio amplifiers and antennas Best Practices Continued ...

Page 42: ...DEVICE ID ZONE NAME PANEL CIRCUIT PWR ENGY DIM NOTES CONTAINS 2x Wire Nuts 2x Mounting Screws 4x Device ID Labels 1x Power Cable The Lightcloud Gateway must be mains powered for permanent installation Power cord including for testing cellular signal strength at different locations in a facility Manual ...

Page 43: ... You must move the Gate way to a location with better cellular signal Solid Yellow Adequate cellular signal This signal strength works for most applications but if possible move to a location with better signal Solid Green Good cellular signal SYSTEM STATUS Blinking Yellow Initializing Solid Yellow Error Cannot reach Lightcloud service Check Cellular Signal Strength and call RAB for technical supp...

Page 44: ...at blade screwdriver and hammer Place the screw driver blade at the edge of the KO then tap the screwdriver with the hammer to weaken the attachment Work your way around the edge of the KO until it breaks away Choose a location with good cellular signal Check your phone s signal for reference NOTE Locations with significant concrete and brick construction or underground locations are not recommend...

Page 45: ...junction box use the junction box s included screws NOTE Conduit must be used to connect to side knockouts 4 Turn breaker back on ON ON 6 STEP FOUR STEP FIVE STEP SIX Install included battery with negative end facing towards junction box area Call RAB to request replacement rechargeable batteries Use RAB provided batteries only Connect hot and neutral wires with included wire nuts ...

Page 46: ...gnal strength LED is yellow or green If the Gateway is powered but this LED is not lit relocate the Gateway to an area with better reception You can use the included power cable to easily test the signal strength in a few locations but remember that the Gateway must be hardwired for perma nent installation 7 9 8 Place extra Device ID stickers on your Lightcloud Device Table see page 18 for future ...

Page 47: ...oller s 0 10V dimming wires place a checkmark here Lightcloud Devices Lightcloud devices that are mains hard wired powered are designed to be installed on a junction box or similar enclosure and must be installed by a qualified electrician Refer to your device s manual for installation considerations and best practices TIP Use extra Device ID stickers on or near your devices or circuits for easier...

Page 48: ... to your Lightcloud network call RAB at 1 844 LIGHTCLOUD Software Setup Lightcloud is cloud based no software to install or maintain ever Once you have a Lightcloud account you can login to lightcloud com at any time to configure and control your system Full Service Need to change something about your system No need to log in RAB can do it for you Call 1 844 LIGHTCLOUD and our support specialists ...

Page 49: ... will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect th...

Page 50: ......

Page 51: ...O HELP RAB Lighting Inc 170 Ludlow Avenue Northvale NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Learn more at lightcloud com ...

Page 52: ...htcloud Dimmer is an in wall switch that connects wirelessly to a Lightcloud Controller to provide switching dimming and scene control Hello Product Features Wireless Control Configuration Zone Switching Dimming Dim Level Indicator Scene Selection Nightlight ...

Page 53: ... 1 77 W x 2 7 H x 1 49 D Faceplate 2 94 W x 4 69 H x 0 06 D Faceplace Bracket 2 8 W x 4 55 H x 0 13 D 18AWG grounding terminals supporting up to 12AWG wire WIRELESS RANGE Line of Sight 1000 feet Obstructions 100 feet Contents Dimmer Faceplate Faceplate Bracket Instruction Manual 2x 6 32 1 2 Screws 2x 6 32 5 16 Screws ...

Page 54: ...hould only be installed by a qualified electrician and in compliance with local and national electrical codes This product should only be installed in a UL approved single gang wall box enclosure Indoor use only What You Need A Lightcloud Gateway A Ceiling Sensor Or similar actuator 1 844 LIGHTCLOUD or 1 844 544 4825 WE RE HERE TO HELP ...

Page 55: ...nother device to the network If there is a clear line of sight between two Lightcloud devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep them within 100 feet of each other Brick concrete and steel construction may require additional AC powered Lightcloud devices to go around the obstruction See the Deployment section of yo...

Page 56: ...rew the line black and neutral white wires into the labeled connectors on the back of the Dimmer Connect the ground wire green 2b Use the two 6 32 1 2 Phillips round head screws to secure the Dimmer to the junction box Make sure the arrow labeled TOP is pointing up ...

Page 57: ...he faceplate onto the faceplate bracket 2c Use the two 6 32 5 16 Phillips flat head screws provided to secure the faceplate bracket to the Dimmer Setup Installation cont d 2 Install the Lightcloud Dimmer cont d ...

Page 58: ... dimming DEVICE IDs ZONE NAME PANEL CIRCUIT 3 Labeling your device 4 Power up To add your Lightcloud Dimmer to your system enable Setup Mode via the Lightcloud application or call RAB at 1 844 544 4825 When the Dimmer powers up it will automatically try to join and keep trying until it is able to join If you are installing multiple devices you may wait until they are all installed to enable Setup ...

Page 59: ...orce device to leave current Lightcloud network DIM LEVEL INDICATOR Displays current dim level Zone mode NIGHTLIGHT White Lit when zone is off so you can find the dimmer SIGNAL STRENGTH INDICATOR Indicates strength of the connection to next Lightcloud Device NETWORK INDICATOR Solid green Connected to a Lightcloud network Blinking red Not connected to a Lightcloud network The network and signal str...

Page 60: ...been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Page 61: ...ctured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Learn more at lightcloud com 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com WE RE HERE TO HELP ...

Page 62: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the ...

Page 63: ...ud Daylight Instruction Manual Mounting Screws Straight Angled Mounting Brackets Power Supply for Setup USB Cable for Setup What You Need Lightcloud Gateway A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices The Daylight is designed to remotely control one or more Lightcloud devices that are capable of switching or dimming such as the Lightcloud Controller or...

Page 64: ...work plug it in with the included Micro USB power adapter The white Power Indicator will come on and the Device Status Indicator will blink red every 10 seconds until it is joined to your network For setup purposes you can plug the device in anywhere that s convenient but please stay near the location where it will be permanently installed in order to ensure continued network connectivity Once set...

Page 65: ...ble if there s enough of it 3 Find a Suitable Location Example of ideal placements 3a A skylight is a great location for the Lightcloud Daylight Be aware of where shadows will land throughout the day and position the device where it will receive the most direct sunlight 3b NOTE Remember south facing surfaces usually receive more direct sunlight than north facing surfaces SKYLIGHT ...

Page 66: ...ure it ends up in direct sunlight as much as possible 3d DIRECT SUNLIGHT Use angled bracket to get more direct sunlight DIRECT SUNLIGHT May need to use an extension to obtain direct sunlight CEILING WINDOW The Daylight must be within range of a Lightcloud device or Gateway See Finding a Location The Daylight will not act as a repeater to extend the range of your Lightcloud network If you need to e...

Page 67: ...pplication will show the last measured light level so you can configure actions to take at different levels Or simply call or email us 5 Configure 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Screw the straight or angled mounting bracket to the mounting surface 4a Snap the Daylight onto the mounting bracket 4b ...

Page 68: ...SB powered Force device to leave current Lightcloud network Hold for 10 seconds while connecting USB power Reset to factory defaults and leave current network DAYLIGHT HARVESTING Daylight Harvesting is the use of daylight to offset the use of electric lighting to light a space If there s enough daylight in a space the Lightcloud Daylight can make sure the lights are turned down or off and turn the...

Page 69: ...Welcome LCCONTROL20 D10 Controller 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com WE RE HERE TO HELP ...

Page 70: ......

Page 71: ...tronic Ballast or LED 277VAC 20A Magnetic Resistive 240VAC 5A Tungsten Electronic 20A FLA 60 LRA 2HP 120VAC 15A Tungsten 1HP OPERATING TEMPERATURE 40ºC to 40ºC OVERALL DIMENSIONS 1 55 diameter 5 75 length 1 2 NPT Mount Male 16AWG pigtails WIRELESS RANGE Warranty is active as long as service plan is active Class 2 IP66 Rated Indoor and Outdoor Rated Wet and Damp Location Plenum Rated Line of Sight ...

Page 72: ...What You Need Lightcloud Gateway A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices 1 844 LIGHTCLOUD or 1 844 544 4825 support lightcloud com WE RE HERE TO HELP ...

Page 73: ... neutral line for the load being switched This enables power measurement See the Power Measurement section under Functionality for more information BLACK WHITE RED 0 10V DIMMING Panel Controller Lightcloud Load BLACK HOT WHITE NEUTRAL WHITE BLACK RED WHITE PURPLE GRAY PURPLE GRAY ...

Page 74: ...e placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep them within 100 ft of each other Brick concrete and steel construction may require additional Lightcloud devices to go around the obstruction Lightcloud Gateway 100 ft Add an additional Lightcloud Device to extend network range around corners BRICK CONCRETE OR METAL WALL DRY WALL OR SIMIL A...

Page 75: ...have an equal or better insulation rating You may need to complete your low voltage wiring in another enclosure or use a partition 0 10V is a common method of low voltage control of dimmable drivers and ballasts Purple 0 10V positive Gray 0 10V common 2a Install at a Junction Box Indoor Outdoor Controller Lightcloud RED WHITE WHITE BLACK GRAY PURPLE WHITE RED To Load To Panel To Driver Ballast ...

Page 76: ... or Trough Space and code allowing you may install Lightcloud devices directly in your breaker box or lighting panel Alternatively break out lighting circuits and install Lightcloud devices in a separate trough WHITE BLACK ...

Page 77: ...o a building manager Attach the Device Identification stickers included with each device to a row then write in additional information such as Zone name Panel Circuit Number and whether or not a zone uses dimming Your Site Name ZONE NAME PANEL CIRCUIT DIMMING Front Desk 2 DEVICE ID 1 1 2 3 To add new devices to your Lightcloud network call RAB at 1 844 LIGHTCLOUD or email us at support lightcloud ...

Page 78: ... 5 STATUS INDICATOR SIGNAL INDICATOR Confirm Device Connectivity Illuminated when device is powered Press once to highlight this device in the Lightcloud Application Press twice and hold to set dim level Press twice to toggle circuit on and off Press and hold for 10 seconds to remove this device from a Lightcloud network Blinks when device is indicated from the Lightcloud Application DEVICE IDENTI...

Page 79: ...le zone TRIGGER Detect when an attached circuit is open or closed For example you could attach the Controller in Trigger mode to an existing occupancy sensor to allow your Lightcloud system to react to the sensor GRAY Controller Lightcloud Load Existing Occupancy Sensor WHITE WHITE BLACK BLACK BLACK BLACK RED PURPLE RED WHITE WHITE WHITE RED 1 844 LIGHTCLOUD or 1 844 544 4825 support lightcloud co...

Page 80: ...ze this function the neutral wire of the load must be connected to the white red sense wire If the Switched Neutral line cannot be used it should be tied to the regular neutral wires i e all neutral wires joined POWER LOSS DETECTION If mains power to the Controller is lost the device will detect this and alert the Lightcloud application EMERGENCY DEFAULT If communication is lost the Controller may...

Page 81: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the...

Page 82: ...e NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system service It s powerful and flexible yet easy to use and install Learn more at lightcloud com ...