REF: REF: LANGAG0419 | V2.00
FITTING INSTRUCTIONS
CLOSE COUPLED PAN & CISTERN
FITTING THE CISTERN TO THE TOILET PAN
With the flush valve and inlet valve fitted and adjusted the cistern
tank can be fitted to the pan.
Fit the gasket around the flush valve outlet on the underside of the
cistern.
When fitting the cistern to the pan take care to ensure the gasket is
properly aligned in the gasket location. Failing to do so could result in
leakage.
Insert the cistern fitting bolts arranging the components as shown in
the diagram below.
Firmly tighten the nuts and wing nuts taking care not to overtighten as
this could damage the ceramic.
MAKING PLUMBING CONNECTIONS
Connect the soil pipe and ensure it is adequately sealed around the
toilet pan outlet to prevent leakage.
The inlet valve has a threaded connector. It is recommended that this
thread is wrapped in PTFE tape before connecting the water supply.
Do not overtighten the supply to the inlet valve as this could damage
the inlet valve causing leakage.
After connecting the water supply to the inlet valve check that the inlet
valve components do not touch the internal walls of the cistern and
the float can move freely up and down.
Check all connections are secure and a soil pipe is fitted before testing
the flush.
Brought to you by the Roper Rhodes Group, Brassmill Lane Trading Estate, Bath, BA1 3JF
TEL: 01225 303 900 (R2) | 01225 787 870 (Tavistock)
Gasket
Fixing bolt
Cistern base
Toilet pan
Metal Washer
Small Rubber
Washer
Gasket
Metal Washer
Rubber Washer
Metal Washer
Rubber Washer
Nut
Rubber Washer
Wingnut
Water supply
connection
Soil pipe
INSTALLING PUSH BUTTON
Fit the push button to the cistern lid using the plastic fixing nut.
Ensure the pins make contact with the flush buttons on the flush
valve. To adjust the length of the rods turn the nut clockwise and
anti-clockwise.
Rod
Nut
Fixing nut
Full Flush
Half Flush
CONNECTION TO WATER SUPPLY
Connect the water supply to the cistern using an approved double
check valve to fluid category 3 in addition to an accessible service
valve.
OPERATION
Press the large button
once
for a large flush (6 litres factory setting)
Press the small button
once
for a small flush (4 litres factory setting)
CARE
DO NOT introduce caustic chemical substances (e.g. containing
chlorine compounds or similar). These can damage the valve
components and cause failure.
This product must be installed by a qualified fitter or plumber in accordance with and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004