6
/ 48
User Manual
Rev. 1.0 - 29/04/21
TEX702TFT
ELETTRONICA
4.4 Description of the Rear Panel
GSM/LAN
R
L
ADJ
TOS
LI
NK
AES/E
BU
SCA1/RDS
RFL FWD
EXT AGC
REMOTE
INTERLOCK IN
R.F. OUTPUT
50
Ω
+
24Vdc
LEFT/MONO
19KHz PILOT
OUT
ADJ
ADJ
10K
Ω
ADJ
RIGHT
PHASE
ADJ
600
Ω
600
Ω
R.F. TEST
max 20dBm
MAINS VOLTAGE
MAINS
FUSE
10K
Ω
CARRIER
FREQ. ADJ
MPX
SCA2
RS
232
SE
RV
IC
E/
R
DS
M
OD
EM
EXT REF
10MHz
Figure 4.2
[1] PLUG
VDE socket for mains power supply.
[2] FAN
Fan for forced ventilation of the transmitter.
[3] R.F. OUTPUT
RF output connector, N-type, 50Ω.
[4] PHASE ADJ
Pilot tone phase adjustment trimmer.
[5] SCA 1/RDS
BNC connector, unbalanced SCA1/RDS input.
[6] MPX
Unbalanced MPX input BNC connector.
[7] MPX ADJ
MPX input level adjustment trimmer.
[8] RIGHT ADJ
Right input level adjustment trimmer.
[9] RIGHT
XLR connector for Right channel audio input.
[10] TOSLINK
Not used (optional).
[11] ADJ L
Not used (optional).
[12] ADJ R
Not used (optional).
[13] SLOT
Not used (optional).
[14] RS232
Not used (optional).
[15] 24VDC IN
Not used (optional).
[16] FUSE BLOCK
Fuse block. Use a screwdriver to access the fuse.
[17] R.F. TEST
Maximum 20dBm referred to the output power level.
[18] CARRIER FREQ. ADJ
Carrier frequency fine adjustment trimmer.
[19] 19KHZ PILOT OUT
Pilot tone output BNC connector, which can be used to
synchronize external devices such as the RDS coder.
[20] SCA 2
BNC connector for SCA2 input.
[21] LEFT/MONO ADJ
LEFT/MONO input level adjustment trimmer.
[22] LEFT/MONO
XLR connector for LEFT/MONO channel audio input.
[23] IMPEDANCE
Dip-switch for selecting the impedance of the balanced
audio inputs, selectable at 600Ω or 10kΩ.
[24] AES/EBU
Not used (optional).
[25] INTERLOCK IN
Interlock BNC connector: by grounding the central
conductor, the transmitter is forced into stand-by mode.
[26] RFL EXT. AGC
Trimmer to control the power delivered according to the RFL
fold input.
[27] FWD EXT. AGC
Trimmer to control the power delivered according to the
FWD fold input.
[28] SERVICE/RDS
DB9 connector for interfacing with other equipment and
factory programming.
[29] REMOTE
DB15 connector for telemetry of the device.
[30] MODEM