5.1 Installation
5.1.1 General Requirements
The ventilation of the equipment and workplace must be suitable for maintenance
according to the directive in force in the country in which this equipment is installed.
To ensure correct operation of the appliance, there must be a clearance of at least
50 cm at the front and back of the device to facilitate the circulation of air through
the ventilation grids.
In any case, the clearances must be in accordance with the safety directive in
force in the country where this equipment is installed.
This device has been designed to operate at temperatures between -10 °C and
45 °C without loss of performance. The ambient air must be dust-free and not
condensed; the maximum humidity must never exceed 95%.
In particular environmental conditions it should be remembered that temperature
fluctuations can cause condensation. If the place where this device is located should
be subject to these physical events, it is advisable to monitor the device once it is
put into service, in addition to trying to protect the device itself as best as possible.
IMPORTANT:
never power up the equipment in the presence of condensation.
This problem can occur more frequently in the case of equipment stored for a long
time or used as active backup.
The RF antenna, power supply and connection cables must have a section suitable
for the maximum current intensity.
5.1.2 Preliminary checks
Unpack the appliance by removing the wrapping and, before any other operation,
check for any damage due to transport. Carefully check that all connectors are
in perfect condition and verify the absence of moisture. Otherwise, wait until it is
completely dry.
If any issues occur during this first phase, contact the after-sales service
immediately.
The main fuse is accessible from the outside on the rear panel. Remove the fuse
block with a screwdriver to check its condition and replace it if necessary. The fuses
to be used are: