EDL600-FM
2 / 6
Instruction manual
Rev. 1.2 - 08/03/07
Abbildung 1: Hintere Tafel
[1] Interlock connectors. BNC with inner normally grounded, floating in case of interlock
[2] Input RF connector RF (N-type)
[3] VDE plug for mains supply (220 AC)
[4] Mains fuses for the fans (1A RAPID)
4. Power Derating
The power that the EDL600-FM can continuosly dissipate depends on the temperature
of the environment.
Since the dummy load can work at a temperature up to 90 °C before the protection
device is triggered, figure 2 gives the acceptable working area of the device.
!
WARNING:
Please remember that it is essential to link the transmitter to the interlock
connectors of the EDL600-FM, to avoid the risk of damaging it.
10
20
30
40
50
60
70
80
200
400
600
800
:DWW
&
7HPSHUDWXU
Illustration 2: Admitted function-types