EDL600-FM

2 / 6

Instruction manual

Rev. 1.2 - 08/03/07

Abbildung 1: Hintere Tafel

[1] Interlock connectors. BNC with inner normally grounded, floating in case of interlock
[2] Input RF connector RF (N-type)
[3] VDE plug for mains supply (220 AC)
[4] Mains fuses for the fans (1A RAPID)

4. Power Derating

The power that the EDL600-FM can continuosly dissipate depends on the temperature

of the environment.

Since the dummy load can work at a temperature up to 90 °C before the protection

device is triggered, figure 2 gives the acceptable working area of the device.

!

WARNING:

 Please remember that it is essential to link the transmitter to the interlock

connectors of the EDL600-FM, to avoid the risk of damaging it.

10

20

30

40

50

60

70

80

200

400

600

800

:DWW

ƒ&

7HPSHUDWXU

Illustration 2: Admitted function-types