TABLE D - MEASURE TESTS CARD
Model VJ10000-TR
Volt Fil.
Current
Fil.
VA
IA
VG1
IG1
VG2
IG2
I° STEP input
4.58 V AC
3.36 V AC 172 mv
-
-
-
-
-
II° STEP input
7 V
6.04 V AC 190 mv
256 mV
549 mV
150 A
575
mV
446 mA
I° STEP Out Test
Point
2.473 V
2.665 V
DC
3.5 V
-
-
-
-
-
II° STEP Out Test
Point
3.9 V
2.9 V DC
3.9 V
3.9 A
3.9 V
3.9 A
3.9 V
DC
3.9 V
DC
I° STEP Strument
Measure
4.4 V
86 A
7000 V
DC
-
-
-
-
-
II° STEP Strument
Measure
7 V
110 A
7500 V
DC
2.5 A
-184 V
30 mA
760
100 mA
I° STEP LCD
Measure
4.5 V
100 A
7 KW
-
-
-
-
-
II° STEP LCD
Measure
7 V
110 A
7.5 KW
2.5 A
- 177 V
30 mA
758
101 mA
I° STEP Fluke
Measure
-
-
-
-
-
-
-
-
II° STEP Fluke
Measure
-
-
-
-
-
-
-
-
On the measure card there are n°2 trimmer P18 corresponding to VG1 voltage presence and
P19 for VA voltage presence.
These two trimmers set the thresholds for the VG1 and IA voltage presence on the
equipment.
Once that is been verified the voltages presence, the relays are closed to enable the
protection box and leds D17 and D19 are light on to signal the controlled voltage presence.
In case that on the equipment is installed a triode tube, the checking of the VG1 is excluded
because this voltage is created automatically when the tube is in power and is created
inserting the jumper JP14 to have a short circuit so that the starting sequence is ok,
otherwise the equipment never go in high tension.
Summary of Contents for 4CX7500
Page 24: ...Date 25 07 03 R V R Elettronica S r l BO VJ10000 TE R F Tube Amplifier 24...
Page 54: ...Date 25 07 03 R V R Elettronica S r l BO VJ10000 TE R F Tube Amplifier 54...
Page 57: ...Date 25 07 03 R V R Elettronica S r l BO VJ10000 TE R F Tube Amplifier 57 Weight 17 6 Lbs 8 Kg...
Page 66: ...Date 25 07 03 R V R Elettronica S r l BO VJ10000 TE R F Tube Amplifier 66...
Page 67: ...Date 25 07 03 R V R Elettronica S r l BO VJ10000 TE R F Tube Amplifier 67...