Figure 5.1:
Voltage selection jumper on PFC
5.1.3 Connections
Connect the RF output of the transmitter (see figure 6.2 - note [21]) to the antenna
cable or a dummy load capable of dissipating amplifier output power. To begin
with, set exciter to minimum output power and switch it off.
Connect the transmitter INTERLOCK IN input (figure 6.2 - note [24]) to the matching
INTERLOCK OUT output fitted on R.V.R. Elettronica equipment to act as hybrid
couplers. If your equipment is a different brand, identify an equivalent output.
WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the
POWER
switch on the front panel (see figure 6.1 - note [11]) is
set to “
OFF
”.
Connect the mains power cable to the MAINS connector on the rear panel (see
figure 6.2 - note [19]).
Note
: The mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.