15
lit, you can adjust by turning selector knob (21) and then press knob in to store.
20. MMA settings
Arc force % : Set this to how much arc force % you require 1-100%
Hot start time : Set this to how much hot start time you require 0.1 - 1.5 Seconds
Hot start amps : Set this to how many hot start amps you require 1 - 100 Amps
21. Selector knob
When turned this will adjust main amperage as shown in display, it will also change
parameters when LED has been selected by using select function buttons. Once you have
adjusted parameter press knob in to save.