Maintenance 

 

 

Routine and periodic maintenance 

 

WARNING! 

 

ELECTRIC SHOCK CAN KILL 

Turn the input power OFF at the mains switch & fuse box before working on this equipment. 

Have a qualified electrician install & service this equipment. 

Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge before 

working inside this equipment. 

 

Do not touch electrically live parts 

 

1.  Periodically remove the side/top panels of machine and clean out machine with a low 

pressure dry air line paying particular attention to PC Boards, Fan blades, HF points 

 

2.  Inspect input and output cables & hoses for fraying, cuts & bare spots 

 

3.  Keep TIG torch and cables in good condition 

 

4.  Clean air vents to ensure proper air flow and cooling 

 

5.  The fan motor has sealed bearings which requires no maintenance 

 

 

 

Troubleshooting 

 

Service & repair should only be performed by R-Tech welding trained personnel. Unauthorised 

repairs performed on this welding equipment may result in danger or injury to the technician and 

machine operator and will invalidate your warranty. 

 

For your safety and to avoid electric shock, please observe all safety notes and precautions 

detailed throughout this manual 

 

The troubleshooting guide is provided to help you locate possible machine malfunctions 

If the fault / problem is not listed below check our support page on our website 

www.r-techwelding.co.uk/support 

or contact R-Tech by phone 

.  

Contact details can be found on front of this manual and our website 

Summary of Contents for TIG160PD

Page 1: ...www r techwelding co uk email sales r techwelding co uk TIG160PD DIGITAL DC TIG WELDER 240V OPERATION INSTRUCTIONS Version 2021 11...

Page 2: ...2...

Page 3: ...PLEASE EXAMINE CARTON AND EQUIPMENT FOR DAMAGE IMMEDIATELY When this equipment is shipped title passes to the purchaser upon receipt from the courier Consequently all claims for material damaged in sh...

Page 4: ...Duty Cycle The R Tech TIG160PD Digital is rated at 160 Amps at 35 duty cycle on a ten minute basis If the duty cycle is exceeded a thermal protector will shut machine off until the machine cools Tech...

Page 5: ...articles towards the welder An abundance of conductive material can cause plant failure Stacking This machine cannot be stacked Transport Unloading Never underestimate the weight of equipment never mo...

Page 6: ...ng these contributing factors in mind installing equipment as per following instructions should minimize problems 1 Keep the welder input power lines as short as possible and enclose as much of them a...

Page 7: ...s equipment Do not touch electrically live parts The TIG160PD DIGITAL Inverter TIG Welder requires a 240V 50 60Hz supply It comes with a 3 metre mains cable attached Connect wires according to nationa...

Page 8: ...hassis If experiencing localized interference when using machine connect workbench to this point using correct graded earth wire not normally used 3 Gas input connector Connect input gas hose ensuring...

Page 9: ...to by inserting and twisting until Tight and the earth clamp to work bench 4 Torch control socket 7 Pin Connect torch control plug To avoid a High Frequency shock keep the TIG torch in good condition...

Page 10: ...Welding Fig 3 1 Negative power connector Connect the earth lead to by inserting and twisting until Tight and the earth clamp to work bench 2 Positive power connector Connect the electrode holder by i...

Page 11: ...0 5 seconds The main welding current decreases from main amperage to minimum amperage in time selected when weld finished 3 Main current control This adjusts the main welding current and is shown in...

Page 12: ...ned on and the arc will be started After the arc is started the output current will increase from the start min current to base main current in time selected by slope up Release the TIG torch switch t...

Page 13: ...he gas keeps flowing after weld has finished this cools stops tungsten from getting contaminated 10 Base current control Pulse min current adjustment This sets pulse minimum base amperage as of main a...

Page 14: ...4T mode when trigger is pressed and held you will remain at start amps when you let go the machine will then go to main set amps Do not set the start amperage too low for tungsten size otherwise you m...

Page 15: ...save Pre Programmed Memory Stores The 9 memory channels have been pre programmed with settings below Memory No Mode Pre flow gas seconds Start amps Slope up seconds Amps peak Base amps Pulse width Pu...

Page 16: ...be dangerous Keep your head out of fumes gases produced from welding Use ventilation or exhaust to remove fumes gases from breathing zone and general area WARNING WELDING SPARKS can cause fire or exp...

Page 17: ...k resulting in a smaller heat affected zone which results in fewer deformations and reduced chance of cracking Welding in TIG mode with Remote foot pedal 1 Connect the TIG Torch to machine connect ear...

Page 18: ...t MMA electrode holder to terminal on machine Fig 3 2 2 Fit earth lead to terminal on machine and to work piece Fig 3 1 3 Select stick on front panel Fig 4 22 4 Place electrode in holder 5 Select desi...

Page 19: ...TIG torch and cables in good condition 4 Clean air vents to ensure proper air flow and cooling 5 The fan motor has sealed bearings which requires no maintenance Troubleshooting Service repair should o...

Page 20: ...tput Power light is lit Gas at torch end when trigger pressed Check torch condition possible break in torch power cable replace torch Machine keeps overheating Warning light is lit on machine Check if...

Page 21: ...as hoses Black areas along weld bead 1 Clean any oily or organic contamination from the work piece 2 Tungsten electrode contaminated Replace or sharpen 3 Check for leaks or contamination on gas hoses...

Page 22: ...ng current set to high reduce amperage or use thicker electrode Contaminated electrodes or material Electrode sticks in weld puddle Welding current is set too low Arc is too short keep electrode furth...