background image

 

15 

 

 

 

 

 

 

 

 

 

Summary of Contents for ProArc 135

Page 1: ...www r techwelding co uk Email sales r techwelding co uk Tel 01452 733933 Fax 01452 733939 ProArc 135 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2014 1...

Page 2: ...2...

Page 3: ...on can be found on data plate at rear of machine Product PROARC135 Serial No ___________________________________ Date of Purchase _____________________________ Where Purchased ________________________...

Page 4: ...R Tech PROARC135 is recommended for the MMA welding processes within its output capacity of 135 Amps DC Equipment Limitations The R Tech PROARC135 is protected from overloads beyond the output ratings...

Page 5: ...cles towards the welder An abundance of conductive material can cause plant failure Stacking This machine cannot be stacked Transport Unloading Never underestimate the weight of equipment never move o...

Page 6: ...and cracks that allow high frequency leakage 4 Keep the torch in good repair and all connections tight to reduce leakage 5 Keep earth lead connection to work in good condition Clean area on workbench...

Page 7: ...s cable attached Connect wires according to national coding Brown wire Live Blue wire Neutral Green Yellow Wire Earth Ground Front machine connections Fig 1 1 Negative welding power connector Connect...

Page 8: ...8 Rear machine connections Fig 2 1 On Off Switch This switches machine on off 2 Mains input cable Connect electrical plug as required...

Page 9: ...at thermostat protection has occurred due to over work or poor airflow Fan will continue to run and once machine has cooled down light will go off and machine is ready to use Note This light will come...

Page 10: ...n be dangerous Keep your head out of fumes gases produced from welding Use ventilation or exhaust to remove fumes gases from breathing zone and general area WARNING WELDING SPARKS can cause fire or ex...

Page 11: ...e input power OFF at the mains switch fuse box before working on this equipment Have a qualified electrician install service this arc welding equipment Allow machine to sit for 5 minutes minimum to al...

Page 12: ...1 No output LED display is not lit Check machine on off switch is in the on position Check Input power to machine Check plug wiring Check mains trip fuses 2 No output Fan runs LED display is lit Warni...

Page 13: ...dirty clean before welding 2 Excessive Splatter Long arc get electrode closer to work Welding current too high reduce welding current 3 Insufficient penetration Too fast welding speed slow down travel...

Page 14: ...14...

Page 15: ...15...

Reviews: