7-4
4.
While using the ViewPort GUI and referring to the packing list/specification sheet, verify
the following:
Occasionally, there may be recorded errors during the initial startup
sequence. However, they typically can easily be reset when the clear
function is initiated.
a)
Under the Cheetah directory, click on
Frame Controller Status
. Verify there are
no alarms and the MFC configuration (single or dual) is correct as per your
specification.
b)
Under the Cheetah directory, click on
Inputs
. Verify there are no errors and the
input module (card) configuration is correct as per your specification.
c)
Under the Cheetah directory, click on
Outputs
. Verify there are no errors and the
output module (card) configuration is correct as per your specification.
d)
Under the Cheetah directory, click on
Matrices
. Verify there are no errors and the
matrix module (card) configuration is correct as per your specification.
e)
Under the Cheetah directory, click on
Power Supplies
. Verify there are no errors
and the power supply module configuration is correct as per your specification.
f)
Under the Cheetah directory, click on
Communications Summary
. (This display
window is used as an overview of all system components.) Verify the status for each
component (4) is indicating green and there are no errors being displayed.
5.
Frame Control Verification is complete. Exit the ViewPort program and disconnect the
serial cable from the PC and MFC. If your system includes the 3500 Series controller
module(s), proceed to System Control, Section 7.4.
Summary of Contents for PESA CHEETAH 128 Series
Page 105: ......