background image

5. ELECTRICAL CONNECTIONS

REMEMBER 

-Turn off the power!

NOTE:

 The fan comes with 80 in. lead 

wires for use with an extended ball 
/downrod assembly. If using the 4 in. or 6 
in. ball/downrod assembly provided, you 
can cut the lead wires to your desired 
length (no shorter than 12 in.).

Use the wire nuts supplied with your fan 
when making connections.  Secure the 
connectors with electrical tape and make 
sure there are no loose connections or wire 
strands.

1.   Motor to capacitor (on the hanging 
bracket) electrical connections: 

(Fig. 11)

● Connect the grey wire from the fan 

to the grey wire from the capacitor.

● Connect the pink wire from the fan 

to the pink wire  from the capacitor.

● Connect the red wire from the fan to 

the red wire from the capacitor.

● Connect the yellow wire from the 

fan to the yellow wire from the 
capacitor.

2.   Capacitor (on the hanging bracket) 
to house supply wires electrical 
connections: 

● Connect the white wire from the 

capacitor to the white wire from the 
house supply wire.

● Connect the black wire from the 

capacitor to the black wire from the 
house supply wire.

● Connect the green wires from the 

fan and hanging bracket to the 
household ground wire.

3.  Inside the ceiling junction box be sure 
to spread the wires apart so that the black 
connection is on one side of the outlet box 
and the white/white and green/copper 
connections are on the other side.

4.    Connect the wiring from the wall 
switch receptacle to wall control unit.

     

● Remove the existing wall plate and 

switch from the wall junction box

● Connect the Black wall wire running 

to the fan to the Black wire (labeled 
“To fan”) from the wall control.

● Connect the other Black house 

supply wire in wall to the Black wire 
(labeled “TO POWER SUPPLY”) to 
the remaining Black wire from the 
wall control (labeled “A/C supply 
source).

5.   If the junction box has a ground wire 
(green or bare copper), connect the wall 
control's ground wire to it. Otherwise, 
connect the wall control ground wire 
directly to one of the screws from the 
outlet box.

6.   Carefully tuck the connected wires 
inside the junction box. Secure the wall 
control with the two screws provided. 
Attach the face plate over the wall control 
with the two screws provided.

Use 

ONLY

 wall controls approved by 

Quorum. Use of unapproved wall 
controls will cause unacceptable 
humming noise, and avoids the fan 
warranty.

Hook up in "series only" do 

not

 connect 

the hot and neutral wires of electric 
circuit to the wall control - damage to 
the wall control and possible fire could 
occur. 

Fig. 11

Fan canopy

Outlet box

Wall control

Ceiling

House 
supply 
wire

House 
supply 
wire

GROUND

NOTE: 

It may be necessary to bind 

the house wires to the corresponding 
receiver wires with electrical tape 
before capping them with wire nuts.  
This will prevent them from slipping 
apart during the rest of the installation.

White

Black

Black

Grey

Grey

Pink

Pink

Yellow

Red

Green

Green

Yellow

Red

Black

White

Hanging 
bracket

Capacitor

Summary of Contents for MAIN STREET Aerovon

Page 1: ...uctions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Aerovon 52 60 SUITABLE FOR INDUSTRIAL USE P O Box 961008 Fort Worth TX 76161 817 626 5483 F...

Page 2: ...stions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Lig...

Page 3: ...ain fuse box or circuit panel before you begin the fan installation or before servicing the fan or installing accessories 2 Read all instructions and safety information carefully before installing you...

Page 4: ...hang the fan in locations where no ceiling joist is available a hanger support bar may be required Figure 4 Contact your local dealer for support bars and outlet boxes 3 MOUNTING OPTIONS WARNING TO R...

Page 5: ...the motor assembly Slide the set pin through the hole in the yoke downrod and secure it with the safety lock clip Tighten the set screws on yoke The yoke cover will lower down to conceal the yoke Fee...

Page 6: ...r side 4 Connect the wiring from the wall switch receptacle to wall control unit Remove the existing wall plate and switch from the wall junction box Connect the Black wall wire running to the fan to...

Page 7: ...ironmentally smart choice to cool as well as to help warm your home or office Adjust your HVAC thermostat during fan use to save additional energy and money on your air conditioning and heating utilit...

Page 8: ...possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoying hum Many fan motors do not work quiet...