![Quooker Swap Replacing Download Page 2](http://html1.mh-extra.com/html/quooker/swap/swap_replacing_3786708002.webp)
1
3
2
4
Replacing the COMBI Tank
1. Switch off the tank with the Q-shaped button on the top. Do not unplug it or switch off
the power yet.
2. Run the boiling water and leave it running until the water runs cold. Also run the cold water tap.
3. Close the main shut-off valve or stopcock. Run the boiling-water tap. If it is depressurised,
no water will flow out of it.
4. Unplug the tank and disconnect the LED cable from the back of the tank cover. Disconnect
the flexible hose between the tap and the tank using spanners 10 and 14. Disconnect
the other two hoses from the reservoir with spanners 17 and 24. Remove the tank from
the kitchen cabinet.
en
Off
Prepare for transport
Drain the Tank by holding the inlet hose
above the sink and the other hose up.
The Tank will empty by itself. Use the two
plugs supplied to seal the two hoses from
the Tank so that they cannot leak during
transport. Screw the correct plug onto
each of the two hoses.