background image

Upgrading a Scale Control Plus 

to a Scale Control R

Summary of Contents for Scale Control Plus

Page 1: ...Upgrading a Scale Control Plus to a Scale Control R...

Page 2: ...Please be sure to follow the correct installation procedure based on the type of tank already present You can check the tank s serial number to determine its type Type PRO3 B Serial numbers beginning...

Page 3: ...ed reducing coupler Coupling piece 3 Scale Control R Meter metal washer screw and sticker 4 Total Hardness Test Kit 5 Copper pipe coupling nuts 2x and clamping rings 2x 15mm not included Not included...

Page 4: ...old water tap at the same time Close the isolation valve 3A then stop the boiling water tap 3 Disconnecting the Scale Control Plus Unscrew both part B and C and disconnect the scale control including...

Page 5: ...ect the scale control including the coupling piece and fibre washer at C 4 Installing the copper pipe Install the copper pipe between the T piece and inlet combination valve Including the coupling nut...

Page 6: ...long to the reducing coupler 2 Connecting the outlet hose Connect the Scale Control R outlet hose short to the tank inlet hose with the blue fibre washer 3 Flushing out the cartridge Open the isolati...

Page 7: ...oupler 2 Connecting the outlet hose Connect the Scale Control R outlet hose short to the tank inlet hose with the coupling piece and blue fibre washers 3 Flushing out the cartridge Open the isolation...

Page 8: ...e out of its box Take a sample of water from the mains cold water feed Rinse out the test bottle with this sample water then fill to the 5 ml mark 2 Adding reagent Slowly add the reagent drop by drop...

Page 9: ...life of the cartridge is determined by the Scale Control R Meter This sounds an alarm signal when the cartridge needs to be replaced Section E describes how to install this meter Cartridge 1 Lifespan...

Page 10: ...inside port closest to the centre of the Quooker tank 3 Mounting the metal washer Screw the washer provided into the kitchen cabinet using the screw provided 4 Securing the Scale Control Plus Meter Mo...

Page 11: ...tting tank type Turn the wheel again to set the power in kW in correspondence with the type of tank you have see table below Press the wheel when the correct value is highlighted Press again to choose...

Page 12: ...n valve PRO3 E 2 Replacing the cartridge Detach the saturated cartridge by unscrewing it out of the head and replace it with a new one 3 Flushing out the system Open the isolation valve PRO3 B or the...

Page 13: ...GSE00084 UKENG V01 Quooker UK Ltd Beaumont Buildings Great Ducie Street Manchester M3 1PQ 44 0 207 923 3355 service quooker co uk www quooker co uk...

Reviews: