Replacing the cartridge
• The cartridge must be replaced before it becomes completely saturated.
• The ‘Q’ on the top of the tank is the on / off switch.
• When installed with a Meter: If it is not possible to replace the cartridge when the alarm
sounds, you can temporarily snooze it (for 72 hours) by pressing the wheel on the Scale
Control Plus Meter.
Scale Control Plus
cartridge
Reduces limescale
Step 1 When alarm sounds, 0% blinks.
Step 2 Unscrew the old cartridge (counter
automatically.
Step 3 Screw in the new cartridge
(clockwise).
Step 4
The Scale Control meter is 100%.
Step 5 Run boiling water for 20 seconds.
Step 6 Check for leaks.
Operational data
Life span: 550L @ 15 dH
Max pressure: 8.6 bar
Temperature range: 2-38°C
Service and order: www.quooker.com
• Only to be connected to drinking water.
•
cartridge prior to use.
• Please dispose this cartridge with your
general waste.
1. Releasing the pressure
Press the on/off switch at the top of the
tank to switch it off. Dispense boiling and
cold water together in order to release the
pressure from the system and then close
it once again when the water runs cold.
Close the inlet combination then turn off
the mains water supply.
2. Replacing the cartridge
Detach the saturated cartridge by twisting
it out of the head and replace it with
a new one.
3. Flushing out the system
Open the inlet combination, then turn
on the mains water supply. Ventilate the
system by opening the boiling water tap.
Flush the system with 20 litres of water
until the water runs clear. Turn on the tank.
Once the water has heated up again, the
Quooker system is ready to use.
4. When installed with a Meter: resetting
the Meter
Turn on the Meter by pressing the wheel
once. Turn the wheel to ‘reset’ and press
the wheel to confirm.