The operation of the Quooker VAQ E

The Quooker system consists of a small tank under the sink which is connected
to the Nordic boiling-water tap or the Fusion tap. The tank is vacuum-insulated
and is connected to the cold water supply via an inlet combination. Inside the
tank the water is heated electrically to approx. 110°C and is kept at this
 temperature. When boiling water is drawn off, cold water flows into the tank at
the same time and is heated automatically. If the entire content of boiling water
is used in one go, the heating-up time is ca. 10 minutes (PRO3-VAQ E) to 
15 minutes (PRO7-VAQ E). 
Before the water leaves the tank it is purified by the HiTAC

®

water filter (High

Temperature Activated Carbon). The Nordic boiling-water tap and the Fusion
tap are insulated and are fitted with a childproof push-and-turn handle (see ‘Tips
for use’ for instructions). When the tap handle is touched an light ring lights up
to alert the user that it is a boiling-water tap. The Nordic boiling-water tap is
also height-adjustable.
The Quooker has been fitted with various safety features. Nevertheless, caution
should always be applied when using boiling water – whether dispensed from
the Quooker or otherwise. Children should not use the tap unattended and
 people not familiar with the tap should be advised on how to use it properly. 

Installation, maintenance and warranty

The Quooker can be installed in almost any location provided there is sufficient
space for the tank as well as a 13 amp socket, water supply and waste. 
The Quooker tank must be fitted in an upright position. If the tank is to be fitted
in a cabinet with drawers, an optional bracket can be purchased to suspend the
tank from the cabinet wall.
The HiTAC

®

filter should be changed once every five years. If you live in a hard

water area, lime scale will collect at the bottom of the tank and will need to be
cleaned out by one of our engineers approximately once a year depending on
usage and the quality of the water in your area. Alternatively, you can install a
suitable descaling system. This system must not reduce the pH level of the
water below 7 or remove all the minerals from the water (reverse osmosis) as
this can be harmful to the tank and would void the warranty. Suitable descaling
systems are also available directly from Quooker as an optional extra.
The warranty period is two years and covers supply of parts only. It does not
cover labour costs or issues resulting from insufficient lime scale maintenance.

Introduction

Summary of Contents for PRO3-VAQ E

Page 1: ...Installation guide VAQ E Before installing read this guide first...

Page 2: ...ter whether dispensed from the Quooker or otherwise Children should not use the tap unattended and people not familiar with the tap should be advised on how to use it properly Installation maintenance...

Page 3: ...ns pressure 200 kPa 2 bar 200 kPa 2 bar Max mains pressure 600 kPa 6 bar 600 kPa 6 bar Max working pressure 800 kPa 8 bar 800 kPa 8 bar Mounting bracket optional yes yes Safety features maximum temper...

Page 4: ...usion tap small washers brass fixing plate fixing nut white tap support for thin work tops and two inlet hose screens 3 Quooker inlet combination 4 Pressure reducing valve 5 PVC connector Quooker dril...

Page 5: ...c tap C Connecting water D Connecting waste E1 Connecting tank with Nordic tap NOTE Bear in mind that the tank inlet combination mixing valve and socket must remain accessible for servicing For an ove...

Page 6: ...order A Drilling hole B2 Fitting Fusion tap C Connecting water D Connecting waste E2 Connecting tank with Fusion tap NOTE Bear in mind that the tank inlet combination mixing valve and socket must rema...

Page 7: ...Nordic boiling water tap has a reach of 16 cm from the centre of the tap hole keep this in mind when choosing the tap position 1 2 3 A 1 Select position boiling water tap Select a suitable position f...

Page 8: ...ecuring tap screws Tighten the screws in the screw ring 1 2 Fitting Nordic tap NOTE The total length of the hose between the boiling water tap and tank is only 70 cm The tank must therefore be fitted...

Page 9: ...go is facing the user When the handle is in the cold position it will be parallel to the edge of the work top Tighten the fixing nut with a pipe wrench socket wrench or spanner 3 Fitting to thin work...

Page 10: ...llow the expansion water to flow away and to prevent water from backing up from the waste pipe see the figure at step D4 1 Cutting through cold water pipe Close the main shut off valve Cut through the...

Page 11: ...ed drill and tap in one operation a threaded hole in the waste pipe Drill slowly so that the PVC does not melt Turn back anti clockwise to preserve the thread 2 Fit connector First try to screw the PV...

Page 12: ...shers or sealants than the ones supplied 1 2 3 4 1 Connecting tank Place the tank in position and connect the inlet hose to the inlet combination with the large fibre washer supplied Connect the tap h...

Page 13: ...alants than the ones supplied 1 2 3 4 1 Connecting tank Place the tank in position and connect the inlet hose to the inlet combination with the large fibre washer supplied Connect the tap hose to the...

Page 14: ...ion tap and leave the water running until it is cold Then close the tap again 3 Isolating Close the main shut off valve or the stop valve on the inlet combination small grey knob Check that the Quooke...

Page 15: ...agnetic Compatibility Directive 97 23 EG Pressure Equipment Directive And are in conformity with the following standards EN60335 1 2002 A1 2004 A11 2004 A2 2006 A12 2006 A13 2008 A14 2010 A15 2011 EN6...

Page 16: ...UK 30 225 03 V08 Q U O O K E R U K L T D 3 Waterpark Hall Montpellier Mews Salford M7 4ZY UK P 44 0 207 9233355 F 44 0 207 9001590 E mail info quooker co uk Internet quooker co uk www quooker co uk...