12 Type A internals: remove the transparent hose from the metal nozzle at the top. Clean scale
from the inside of the nozzle, use the allen key to remove any blockages. Push the hose back
onto the nozzle all the way.
- Type B internals: move to step 13.
13 Remove the white gasket (G). Ensure that the surface of the plate is dry and clean and put the
new gasket in place.
- Refit the filter.
14 Ensure that the rim of the tank is clean by using the scraper and Scotchbrite.
15 Dry the entire rim including the seams and bolts with paper towel, while holding the tank upside
down at an angle.