background image

2

4

1

3

1. Drilling hole
Using the drill bit supplied, drill and tap 
in one operation a threaded hole in the 
waste pipe. Drill slowly so that the PVC 
does not melt. Turn back anti-clockwise to 
preserve the thread.

2. Fit connector
First try to screw the PVC connector in 
the hole before fitting permanently with 
PVC glue.

3. Connect hose to waste pipe
Slide the waste hose over the PVC 
connector.

4. Connect hose to inlet combination 
valve
Create a u-bend (or loop) in the hose 
and connect it to the funnel of the inlet 
combination valve. The u-bend will 
 create a water lock to block smells from 
the waste pipe. As the water is being 
heated, the inlet combination valve will 
release drips of water into the grey funnel. 
The open funnel is required to prevent 
pressure build-up.

Connecting waste

The Quooker tank releases expansion water via the inlet combination valve which is fed into the 
grey funnel. The funnel is connected to the waste pipe via the  supplied waste hose. The drilling kit, 
also supplied, can be used to make a connection onto the waste pipe. 

It is important to keep the height distance between the inlet combination valve and the 
connection to the waste pipe as large as possible to prevent waste water from flowing back.

D

As high 

as

 po

ssible

Summary of Contents for PRO E

Page 1: ...Installation guide PRO E Before installing read this guide first...

Page 2: ...ncorrect use can lead to injury Therefore always read the manual carefully before use Installation maintenance and warranty The Quooker can be installed in almost any location provided there is suffic...

Page 3: ...and for use by visitors at hotels motels bed breakfasts and other residential accommodation Always follow the installation method described in the manual Avoid spilling water on the plug If defective...

Page 4: ...U Pressure Equipment Directive and are in conformity with the following standards General product safety household and similar electrical appliances EN 60335 1 2012 AC 2014 A11 2014 EN 60335 2 15 2002...

Page 5: ...pressure 200 kPa 2 bar 200 kPa 2 bar Max mains pressure 600 kPa 6 bar 600 kPa 6 bar Max working pressure 800 kPa 8 bar 800 kPa 8 bar Mounting bracket optional yes yes Safety features maximum temperat...

Page 6: ...ll fibre washer brass fixing plate fixing nut white tap support for thin work tops and two inlet hose screens or Flex tap hoses small fibre washer metal washer threaded ring with two screws counterwei...

Page 7: ...2 PRO3 VAQ E tank or PRO7 VAQ E tank 3 Pressure reducing valve 4 Quooker inlet combination valve 5 PVC connector Quooker drill bit two large fibre washers one spare one small fibre washer and waste ho...

Page 8: ...order A Drilling hole B1 Fitting Nordic single tap C Connecting water D Connecting waste E Connecting tank Note Bare in mind that the tank inlet combination valve and socket must remain accessible for...

Page 9: ...der A Drilling hole B2 Fitting Fusion tap C Connecting water D Connecting waste E Connecting tank Note Bare in mind that the tank inlet combination valve and socket must remain accessible for servicin...

Page 10: ...nstall the Quooker in the following order A Drilling hole B3 Fitting Flex tap C Connecting water D Connecting waste E Connecting tank Note Bare in mind that the tank inlet combination valve and socket...

Page 11: ...e for the Nordic single tap should be 32 mm in diameter The Fusion and Flex tap hole should be 35 mm in diameter The Nordic single tap should ideally be positioned at the corner of the sink to enable...

Page 12: ...p screws Tighten the threaded ring and secure it with the two screws provided Fitting Nordic single tap Note The total length of the hose between the single tap and tank is only 70 cm The tank must th...

Page 13: ...r spanner 4 Connecting hoses Insert the inlet hose screens and connect the hot and cold water inlet hoses to the mains Fitting to thin work top When fitting to a thin work top use the white tap suppor...

Page 14: ...user and fully tighten the metal washer 4 Securing tap screws Tighten the threaded ring and secure it with the two screws provided Fitting Flex tap When installing the tank it is necessary to take in...

Page 15: ...rweight s quick release fitting whilst ensuring that the hose stem is fully inserted 7 Connecting hoses Insert the inlet hose screens and connect the hot and cold water inlet hoses to the mains If nec...

Page 16: ...e The VAQ E operates under mains water pressure and must always be fitted with the supplied inlet combination and pressure reducing valves The Nordic single tap the Fusion or the Flex tap must be inst...

Page 17: ...valve The u bend will create a water lock to block smells from the waste pipe As the water is being heated the inlet combination valve will release drips of water into the grey funnel The open funnel...

Page 18: ...ilter and completely harmless 4 Switching on tank Switch on the tank After the water has heated up the entire content of the Quooker must be flushed out once before use Connecting tank to tap The Quoo...

Page 19: ...valve or the stop valve on the inlet combination valve small grey knob Check that the Quooker is depressurized by opening the boiling water handle of the tap again If it is depressurized no water sho...

Page 20: ...Quooker UK Ltd Beaumont Buildings Great Ducie Street Manchester M3 1PQ UK 0207 9233355 info quooker co uk quooker co uk UK 30 225 03 V18...