1. Connecting tank
Put the Quooker tank into position and 
connect the hoses. The hoses have 
compression fittings and therefore do not 
need any gaskets. Connect the tap hose 
with the washer to the fitting on the top of 
the tank. 

2. Electrical connection
Connect the boiling-water tap by plugging 
the LED cable into the hole provided at 
the back of the tank cover. Connect the 
tank to the socket. Switch the socket on 
but not the tank yet.

3. Filling tank
Open the boiling-water tap and the stop 
valve on the inlet combination. Check 
for leaks. Flush the tank through until the 
water is clear. Black water will flow out 
initially. This is Norit carbon from the  filter 
and completely harmless.

4. Switching on tank
Switch on the Quooker. After the water 
has heated up, the entire content of the 
Quooker must be flushed out once 
before use.

Connecting tank

•  The Quooker tank is supplied with a UK 3 pin plug and requires a standard 13 amp 
  earthed socket.  
•   If the mains lead is damaged it should be replaced by the manufacturer, their agent or a 
  qualified technician to prevent hazard. 
•   The light ring on the boiling-water tap will light up to indicate when the water is being heated 
  inside the tank. 
•   The Q-shaped button on top of the tank is the on/off switch.

E

10

14

On/off

Summary of Contents for Combi+

Page 1: ...Installation guide COMBI Before installing read this guide first...

Page 2: ...safety feature the Nordic single tap is height adjustable and the Nordic single tap the Fusion tap and the Flex tap are fully insulated Despite all the safety features incorporated in the product any...

Page 3: ...for use by visitors at hotels motels bed breakfasts and other residential accommodation Always follow the installation method described in the manual Avoid spilling water on the plug If defective the...

Page 4: ...e And are in conformity with the following standards General product safety household and similar electrical appliances EN 60335 1 2012 AC 2014 A11 2014 EN 60335 2 15 2002 AC 2005 A1 2005 AC 2006 A2 2...

Page 5: ...tion thermostatic Mounting bracket available yes Safety features maximum temperature limit pressure relief valve 800 kPa 8 bar HiTAC water filter High Temperature Activated Carbon These are average va...

Page 6: ...sion tap packing ring brass fixing plate fixing nut white tap support for thin work tops and two inlet hose screens or Flex tap hoses fibre washer s steel washer screw ring with two screws coupling wi...

Page 7: ...r inlet combination waste hose Quooker drill bit PVC connector and large packing rings 4 Mixing valve 5 T joint pressure reducing valve warm with 15 12 adapter pressure reducing valve cold 15 mm olive...

Page 8: ...order A Drilling hole B1 Fitting Nordic single tap C Connecting water D Connecting waste E Connecting tank Note Bear in mind that the tank inlet combination mixing valve and socket must remain accessi...

Page 9: ...Drilling hole B2 Fitting Fusion tap C Connecting water D Connecting waste E Connecting tank Note Bear in mind that the tank inlet combination mixing valve and socket must remain accessible for servici...

Page 10: ...ommended that you install the Quooker in the following order A Drilling hole B3 Fitting Flex tap C Connecting water D Connecting waste E Connecting tank Note Bear in mind that the tank inlet combinati...

Page 11: ...r the Nordic single tap should be 32 mm in diameter The Fusion and Flex tap hole should be 35 mm in diameter The Nordic single tap should ideally be positioned at the corner of the sink to enable use...

Page 12: ...lied 3 Securing tap screws Tighten the screws in the screw ring Fitting Nordic single tap The total length of the hose between the boiling water tap and tank is only 70 cm The tank must therefore be f...

Page 13: ...w the fixing nut onto the tap thread Adjust the position of the tap to ensure that the Quooker logo is facing the user When the handle is in the cold position it will be parallel to the edge of the wo...

Page 14: ...the work top 3 Tighten the brass plate Put the tap in the required position and fully tighten the brass plate 4 Securing tap screws Tighten the screws in the screw ring Fitting Flex tap When installi...

Page 15: ...mixer water hose Click the mixer water hose into the coupling s quick release fitting while ensuring that the hose pillar is fully inserted If necessary Detach coupling Use the quick release tool to d...

Page 16: ...e pressure reducing valve warm to the hot water pipe In case of a 15 mm pipe replace the 15 12 mm adaptor in the coupler with the 15 mm olive 12 mm 15 mm Connecting water The COMBI operates under main...

Page 17: ...the inlet combination will release drips of water into the grey funnel The open funnel is required to prevent pressure build up Connecting waste The water in the Quooker tank expands as it heats up Th...

Page 18: ...ck for leaks Flush the tank through until the water is clear Black water will flow out initially This is Norit carbon from the filter and completely harmless 4 Switching on tank Switch on the Quooker...

Page 19: ...main shut off valve or the stop valve on the inlet combination small grey knob Check that the Quooker is depressurized by opening the Nordic single tap or the boiling water handle of the Fusion or Fl...

Page 20: ...Quooker Hong Kong Limited 10 F YF Life Tower 33 Lockhart Road Wanchai Hong Kong info quooker hk www quooker hk HK 30 227 15 V01...

Reviews: