Quoizel T0169 Assembly And Installation Instructions Download Page 2

Page 2 / 5

Sensor

Turn on the power at fuse or circuit  box.

sensor

Fig. 1

Installation Steps

Turn off the power at fuse or circuit box.

Mounting Strap (A)

Outlet Box

Wire Connector (D)

Back Plate

Mounting Screw (B)

Light Head

Fixture Mounting Screw 

FRONT

Decorative cover (C)

1. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using 

    two mounting screws that best fit the outlet box.

2. Pull out the source wires from the outlet box. Make wire connections using wire connectors as follows:

     ---Connect the black wire from the fixture to the black wire from the power source.

     ---Connect the white wire from the fixture to the white wire from the power source.

     ---Connect the grounding wire from the fixture to the grounding wire from the power source. (usually green / yellow 

         insulation)

     Carefully tuck the wires back into the outlet box.

3. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw.

4. Push the decorative cover firmly into the fixture mounting screw hole on the light fixture.

5. With silicone caulking compound, caulk completely around where the back plate meets the wall surface.

  CAUTION: Be sure to caulk completely where the back plate meets the wall surface to prevent water from 

    seeping into the outlet box.

150105

Adjusting the Sensor Head: 

1. Aim sensor head toward desired detection area, maintaining a 5° - 15° 

    downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with control knob facing 

    towards the ground.

2. You can move the sensor head up and down to change the coverage area. 

    (See Fig. 2) Walk through the detection zone at the farthest distance you wish

    to detect motion.

    

Note: Range set too high may increase false triggering.

 

    (See Fig. 2 and Fig. 3 )

Adjustment Sensor Lower For Short Coverage

Adjustment Sensor Higher For Long Coverage

Fig. 2

Fig. 3