QUNDIS Q heat 5 Ultrasonic Operating Manual Download Page 2

2

3

Contents

Important information

This product must be installed professionally and in accordance with the pre-

scribed assembly guidelines and may therefore only be installed by qualified 

and trained experts.

Application according to specification

The heat meter is used for the centralised recording of the consumption of 

heating energy. The heat meter must be used exclusively for this purpose. The 

medium is made up exclusively of water without chemical additives.

Use not according to specification

Any use other than the use described previously and any changes made to the 

device constitute improper use. Uses and changes must be queried in writing 

beforehand and are subject to special approval.

Warranty and guarantee

Warranty and guarantee claims are only valid if the parts in question have been 

used in accordance with their intended use and if the technical requirements 

and any applicable technical regulations have been observed.

Safety notes

Improper handling and excessively forceful tightening of screwed connections 

can cause leaks. Observe the maximum torque stated in the manual. The 

dimensions and thermal loads of seals must be appropriate for their application. 

You should therefore only use the seals delivered with the device. Only use 

water without chemical additives as the medium for this device.

The installed meter is a pressurized component.

There is a risk of persons suffering scolds from hot water.

Safety and warranty

Safety and warranty ...................................................................................... 3
Safety of lithium batteries............................................................................. 4

Safety notes for lithium batteries .................................................................. 4

Technical data ................................................................................................ 5

Norms and standards ................................................................................... 5

Calculator unit ............................................................................................... 5

Technical data ................................................................................................ 6

Flow sensor .................................................................................................. 6

Temperature sensor ...................................................................................... 6

Device elements ............................................................................................ 7

Device elements ........................................................................................... 7

Key assignment in standard mode ............................................................... 7

Status displays ............................................................................................. 7

Display ............................................................................................................ 8

Operating scheme ........................................................................................ 8

Fast readout mode ....................................................................................... 8

Standard loop ............................................................................................ 8

Error messages ......................................................................................... 8

Display ............................................................................................................ 9

Overview of levels ........................................................................................ 9

Display level L0 – Current consumption values .......................................... 10

Display level L1 – Annual consumption values ........................................... 10

Display level L2 – Current values ................................................................11

Display level L3 – Parameters .................................................................... 12

Display level L5 – Monthly values heat ...................................................... 13

Display level L9 – Current values ............................................................... 14

Special operating states ............................................................................. 14

Error messages .......................................................................................... 15

Summary of Contents for Q heat 5 Ultrasonic

Page 1: ...1 Q heat 5 Ultrasonic Heat meters Operating manual IMPORTANT READ THROUGH CAREFULLY BEFORE USE KEEP ACCESSIBLE THROUGHOUT THE PRODUCT LIFETIME ...

Page 2: ...r handling and excessively forceful tightening of screwed connections can cause leaks Observe the maximum torque stated in the manual The dimensions and thermal loads of seals must be appropriate for their application You should therefore only use the seals delivered with the device Only use water without chemical additives as the medium for this device The installed meter is a pressurized compone...

Page 3: ...USE WATER FOR EXTINGUISHING PURPOSES Do not use CO2 halogen fire extinguishers with dry substances or foam extinguishers Move away from the accident spot following inhalation and ventilate the area Always consult a doctor Safety notes for lithium batteries Technical data CE conformity see Declaration of Conformity Electromagnetic compatibility Interference resistance EN 61000 6 2 Emitted interfere...

Page 4: ...ess the H key or press the V key 2 To change from any position on one level to the next level Press the H key 3 To change to the next display within one level Press the V key Flow sensor Temperature sensor Measuring element PT 1000 according to EN 60751 Version Type DS Diameter 5 0 mm 5 2 mm Type of installation 5 0 mm direct ball valve indirect immersion sleeve 5 2 mm direct ball valve indirect i...

Page 5: ...ate are displayed be fore the meter status If the incorrect direction of flow is established an error message appears on the display as shown Operating scheme Display L0 L1 L2 L3 L5 L9 Current consumption values Standard level Annual consumption values Standard level Current values Can be hidden individually Parameter Can be hidden individually Monthly values heat Can be switched off individually ...

Page 6: ... date Checksum alt alt alt The displays coloured grey are optional or can be added and switched off as required Annual consumption values Heat Display Display level L2 Current values alt Displays the level Current flow Current supply flow temperature Current return flow temperature Current temperature difference Current energy flow Operating hours Cumulated volume High resolution meter status heat...

Page 7: ... and 8 not available level 9 hidden Calibrated checksum firmware version Serial number Calibrated firmware version alt alt Display Display level L5 Monthly values heat Displays the level Oldest monthly value heat alt alt alt Latest monthly value heat alt alt alt Date Serial number Checksum Meter status The displays coloured grey are optional or can be added and switched off as required ...

Page 8: ... of installation of temperature sensor Air in the measuring section No correct ultrasonic meas uring signal Bleed the pipe system Error messages Display Error display Error description Measures Notes Hardware error or damaged firmware Check flow sensor connection cable and calculator unit for external damage Device must be replaced Add on module was paired with another meter before The module has ...

Page 9: ...098 Erfurt Tel 49 0 3 61 26 280 0 Fax 49 0 3 61 26 280 175 www qundis com Ultrasonic heat meter Operating manual Q heat 5 US Type Ultrasonic measuring technology Document no FOM5ZZHEEN0 USDSP Date published 5 12 2014 Version V3 00 ...

Reviews: