Organoclay filters (second stage)
9
Condensate outlet
10
Test valve
11
Diffuser
12
Test capsule storage compartment
The condensate, containing fine oil droplets, enters the unit via inlets (1) into the mufflers (2) and
is depressurized. The condensate flows to the first tower and seeps through an oleophilic filter
(3), which absorbs most of the oil.
The water from the first stage, still containing a small quantity of oil, gradually flows to a second
stage, where an organoclay filter is fitted (7). The second stage filter starts to absorb the part of
the oil in the condensate. The condensate gradually flows into the third stage where another
organoclay filter is fitted (8).
The clean condensate is drained to the condensate outlet (9).
The oleophilic filter floats on the water. The more oil the filter absorbs, the deeper it will sink, and
service indicator (4) will move downwards with the filter. The filter must be replaced when the
service indicator is down.
QOCS 5300 consists of two units and a flow divider needs to be installed to feed both units equal
amount of condensate.
Instruction book
2920 7197 51