8 RIVA ADVANCE COMBI USER MANUAL
2. Technical Information Cont.
ENERGY CAPACITY
Nominal heat input
(0/2000 ft)
MBH
1
25
.0
Nominal heat input
(2000/4500 ft)
MBH
1
1
2.5
Minimum heat input
MBH
32.0
Maximum useful output
(0/2000 ft)
MBH
1
12.5
Maximum useful output
(2000/4500 ft)
MBH
107.0
Minimum useful output
MBH
28.8
GAS PRESSURE AT BURNER
Gas
Min
Max
Normal
Natural
inwc
6.8
10.0
7
.0
Propane
inwc
10.0
1
3
.0
1
1
.0
FLUE DESIGN
Minimum Venturi pressure
inwc
0.64
Flue pipe diameter
Coaxial
in
2.25/4
3.25/5
Twin split pipes
in
3.25/3.25
Nominal heat flow rate
(0/2000 ft)
MBH
1
25
.0
Nominal heat flow rate
(2000/4500 ft)
MBH
11
2.5
Max Exhaust temperature
°F
190
GAS FLOW RATE
Gas
Min
Max
Natural
ft³/h
31.0
1
21.0
Propane
lb/h
1.5
5.
7
CLEARANCE TO COMBUSTIBLES
Front
in
18
Back
in
0
Top
in
10
Sides
in
2
Bottom
in
8
Flue pipe enclosed
in
2
Flue pipe free air
in
0
Hot water pipes
in
1”
FLUE GAS FIGURES
(at nominal heat input)
Gas
Min
Max
CO
2
content with Natural gas
8.8
%
9.8%
CO
2
content with Propane gas
9.6
% 11.0%
O
2
content
4.3%
5.0%
FLUE GAS FIGURES
(at minimum heat input)
Gas
Min
Max
CO
2
content with Natural gas
8.8
%
9.8%
CO
2
content with Propane gas
9.6
% 11.0%
O
2
content
4.3%
5.0%
DOMESTIC HOT WATER
Maximum temperature
°F
131
Minimum temperature
°F
95
Maximum pressure
psi
145
Minimum pressure
psi
4.35
D.h.w. ΔT 25°C / 45°F
gpm
4.5
D.h.w. ΔT 30°C / 54°F
gpm
3.8
D.h.w. ΔT 35°C / 63°F
gpm
3.2
D.h.w. ΔT 40°C / 72°F
gpm
2.8
Summary of Contents for Riva ADVANCE COMBI
Page 22: ...22 RIVA ADVANCE COMBI USER MANUAL...
Page 23: ......
Page 24: ...1796220640 17962 2064 0 2712 24A4 USA 06 07 2012 N...