Section VIII - Technical data
• I = 128 A + 25 % = 128 x 1.25 = 160 A
• For AWG2/0, the maximum current is 175 A, which is sufficient => use AWG2/0
• Install the prescribed maximum fuse (150 A) on each cable
• Parallel supply cable (2 x 3 2 PE - configuration (2)):
• I = (128 A + 25%)/2 = (128 x 1.25)/2 = 80 A
• For a AWG4, the maximum current is 85 A x 0.8 = 68 A, which is insufficient. For an
AWG3, the maximum current is 100 x 0.8 = 80 A. So 2 parallel cables of 3 x AWG3
+ 2 x AWG8 are sufficient.
• Install 80 A fuses on each cable.
Reference conditions and limitations
Reference conditions
Relative humidity
%
0
Air inlet temperature
°C
20
°F
68
Exhaust back pressure
mbar(g)
0
psi
0
Ambient barometric pressure
mbar(a)
1013
Psi
14.7
Limitations
Minimum ambient temperature
°C
0
°F
32
Maximum ambient temperature
°C
46
°F
115
Minimum allowable inlet
temperature
°C
-10
°F
14
Maximum allowable inlet
temperature
°C
70
°F
158
Maximum inlet pressure
mbar(a)
1050
Psi
0.73
Maximum vessel pressure
mbar(a)
1500
psi
7.3
Quincy Vacuum Pump-QSV Series
103