8.5
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
See section Compressor data.
Limits
Maximum working pressure
See section Compressor data.
Minimum working pressure
bar(e)
4
Minimum working pressure
psig
58
Maximum air inlet temperature
˚C
46
Maximum air inlet temperature
˚F
115
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
8.6
Compressor data
Reference conditions
All data specified below apply under reference conditions, see section
QGD 40
7.5 bar 8.5 bar 10 bar 100 psi 125 psi 150 psi
Frequency
Hz
50
50
50
60
60
60
Maximum (unloading) pressure
bar(e)
7.5
8.5
10
7.4
9.1
10.8
Maximum (unloading) pressure
psig
109
123
145
107
132
157
Maximum (unloading) pressure, units with
integrated dryer
bar(e)
7.3
8.3
9.8
7.2
8.9
10.6
Maximum (unloading) pressure, units with
integrated dryer
psig
106
120
142
104
129
154
Reference working pressure
bar(e)
7
8
9.5
6.9
8.6
10.3
Reference working pressure
psig
102
116
138
100
125
150
Pressure drop over dryer, units with
integrated dryer
bar(e)
0.25
0.25
0.25
0.25
0.25
0.25
Instruction book
102
2920 7190 02
Summary of Contents for QGD 40
Page 1: ...Quincy Oil injected rotary screw compressors QGD 40 QGD 50 QGD 60 Instruction book...
Page 2: ......
Page 14: ...Front view compressors with integrated dryer Instruction book 12 2920 7190 02...
Page 15: ...Front view open compressors without dryer Instruction book 2920 7190 02 13...
Page 16: ...Rear view compressors without dryer Instruction book 14 2920 7190 02...
Page 17: ...Front view open compressors with integrated dryer Instruction book 2920 7190 02 15...
Page 112: ......
Page 113: ......