www.quikoitaly.com
9.
MAINTENANCE
When carrying out maintenance operation on the controller, disconnect it
from the mains power supply. The actuator does not require periodical
maintenance operations.
• Check the safety devices of the gate and automation.
• Periodically check the pushing force and correct the value of the electric
torque in the control board if necessary.
• In case of unsolved operation failures, disconnect the unit from the main
power supply and ask for the intervention of qualified personnel (instal-
ler).
When the unit is out of order, activate the manual release to perform
manual opening and closing maneuvers.
Anyone using the automation must be instructed in its operation and
controls.
10.
TECHNICAL FEATURES
QK-Z600
QK-Z300B
QK-Z600B
Power
(50/60Hz)
230Vac
24Vdc
24Vdc
Power /
Current
Absorbed
220W
1,1A
100W
4A
210W
8A
Max gate
weight
(kg)
600
300
600
Speed
(m/min)
12
12
12
Protection
rate
(IP)
54
54
54
Thermal
protection
(°C)
140
-
-
Working
temp.
(°C)
-30/+70
-30/+70
-30/+70
Working
Cycle
(%)
60
100
100
Weight
(Kg)
9
8
9