quiko QK-Intkey User Manual Download Page 2

2

 

General: 
The 5 wires encoder unit is an intercom system, serves as door panel and encoder. With this unit you can speak with the 
visitor who is waiting at  the door and open the electric lock from the intercom handset or from the phone using 5 wires  
adapter. Authorized personnel can open the door by pressing an access code.  By programming appropriately, each user 
can  get  an  individual  access  code.  The  device  includes  an  environment  resistant  and  anti  vandal  metal  keyboard.  An 
optional bypass pushbutton enables easy internal opening (the opening time is programmable) 
 
Features: 
Easy installation, programming and 
operating. 

Power failure resistance, keeps the access 
codes in nonvolatile memory 

up to 98 different access codes 

Environmental and anti vandal resistance. 

Different and programmable opening time 
from keyboard and bypass pushbutton  

Up to 1 million possible combination codes  

 
Specifications: 
Operating voltage: AC 12/24V 1000mA   

Code length: 2-6 keys 

Operating electric or magnetic lock. (normally 
open or normally close)   

Opening time: 1-9 seconds 

Size:  154X100X35mm (H*W*D) 

 

Installation: 
Setting J5 Jumper according to the lock type 
Desirable RLY state when entering valid code 

Jumper J5 

Close circuit  (Normally open) for electric lock 

Jumper on 2 left pins (default state) 

Open circuit  (Normally close) for magnetic lock 

Jumper on 2 right pins  

 
After installing the lock in the door frame. Route the following wires to the Intercom Encoder: 
1. 

2 wires from power supply. 

2. 

2 wires from the lock. 

3. 

5 wires from Intercom handset. 

4. 

2 wires from bypass pushbutton (optional). 

 
Using a screwdriver open the top cover, carefully pull up the panel. Expose the 4 covered insulations bores and the round 
wirings bore. Attach the base of the Intercom Encoder to the wall, using a pencil mark the 4 fixing points. Drill the 4 fixing 
points on the wall. Route the wires through the round bore in the base of the Intercom Encoder. Using 4 screws install the 
base to the wall. Verify the power supply is not connected to power source. Connect the wires to the circuit board terminal 
blocks  according  to  the  circuit’s  labels,  the  attached  electrical  diagram  and  the  following  instructions.  Connect:  Power 
supply to the two 12/24VAC terminals. One wire from the lock to the RLY terminal. The second wire from the lock to one 
of  the  12/24VAC  terminal.    Short  wire  from  the  second  12/24VAC  terminal  to  the  second  RLY  terminal.    (The  RLY 
functions as a switch) 

 

Handset wiring 
Several common handsets could be assembled. Electric buzzer handset can not be assembled. If you intend to install a 
bypass pushbutton, connect one wire to RX terminal and the other wire to the 12/24VAC terminal which the handset com 
wire is connected to. Reassemble the panel over the base. Attach the top cover to the base using the 4 screws. Connect 
the power supply to the power inlet, the red led will illuminate, indicating power supply to the Intercom Encoder. The green 
led will blink for 2 seconds indicating correctly initiation. 

 

Programming 
100 memory cells 8 digits long each one, available. Cell 00 is used for door opening times values storage. Cell 99 is used 
for programming code value storage. The rest of the 98 cells from 01 to cell 98 are used for different access codes values 
storage. The code length is minimum 2 digits and ,maximum 8 digits. (recommended 6 digits for programming code, and 4 
digits for access code). Programming code, access codes and opening times values are programmable via the keyboard. 
Programming mode: in order to store new access code, set opening times or changing the programming code, you should 
enter  to  the  Programming  mode.  After  clicking  the  valid  programming  code  (manufacturer  code  if  not  changed  is 

123456 confirm with*) the green led is blinking, now you can do the required programming as described in the following 

examples. When finished you can enter more access codes or exit this mode to the regular state by pressing 

. Each 

key  stroke  is  followed  by  a  Beep  sound,  entering  a  false  code  or  invalid  pressing  is  followed  by  a  “Beep-Beep-Beep” 
sound sequence. Entering a valid sequence to memory cell is followed by a long “Beep” sound. If the programming mode 
is not exit, a timer exits the Intercom Encoder from this mode to a regular mode. 
 
 
 
 
 
 

Summary of Contents for QK-Intkey

Page 1: ...E N G L I S H user m a n u a l QK INTKEY QK INTKEY AUDIO INTERCOM WITH BUILT IN KEYPAD 5 WIRES USER MANUAL AUDIO INTERCOM WITH BUILT IN KEYPAD 5 WIRES ...

Page 2: ...e Connect the wires to the circuit board terminal blocks according to the circuit s labels the attached electrical diagram and the following instructions Connect Power supply to the two 12 24VAC terminals One wire from the lock to the RLY terminal The second wire from the lock to one of the 12 24VAC terminal Short wire from the second 12 24VAC terminal to the second RLY terminal The RLY functions ...

Page 3: ...t to opening via the keyboard and via the optional bypass pushbutton The times values are from 1 second till 9 seconds Enter the programming code if not changed is 123456 the green led will blink Now the following sequence should be entered memory cell number 00 opening time via keyboard 1 digit followed by opening time via bypass pushbutton 1 digit for verification repeat the same sequence of mem...

Page 4: ...4 Connection to electric magnetic lock ...

Page 5: ... E N G L I S H Connection to control board for automatic gates When using 24Vac from the automatic gate control board please connect the supplied resistance to the handset as shown within the image below ...

Page 6: ...6 ...

Page 7: ...7 E N G L I S H ...

Page 8: ...oducts without any prior notice Il Fabbricante può apportare ai suoi prodotti modifiche tecniche migliorative della qualità senza preavviso QUIKO ITALY Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...