background image

       www.quikoitaly.com 

GENERAL ADVICE

Install a gate’s safety system that complies with current regulations. Choose short routes for cables and keep power cables separate 
from control ones. Install the control card in a waterproof box. 

Please refer to current regulations when setting the gear motor’s maximum torque. 

We advice you to install an outdoor switch, in compliance with European standards on the issue of safety, to turn the electricity off when 
servicing the gate. 

Check that each single installed device is efficient and effective. 

Affix easily readable signs warning about the presence of a motorized gate 

USE

It is absolutely forbidden to use the device for any other purposes. The installed control board (which must have built-in electric friction), 
allows to select the following functions: 

automatic:

 one control impulse will open or close the gate; 

semi-automatic:

 one control impulse will open or close the gate. 

In case of a blackout, manual operation is possible by activating the unlocking device.  

Having an automatic and electric power device requires special attention in a few situations:  

not to touch the device with wet hands and/or wet or bare feet; 

to turn off electricity before opening the control box and/or actuator; 

not to pull the lead to pull the plug out; 

to put the gate in movement only when it is completely visible; 

to keep out of the gate’s range of action if it is moving. Wait until it has stopped; 

not to let children or animals play near the gate; 

not to let children use the remote control or other operating devices; 

to carry out routine maintenance; 

in case of failure, to turn off electricity and operate the gate manually only if it is possible and safe. Refrain from touching 
the gate and call an authorized technician. 

MAINTENANCE

The ERCOLE is a gear motor  for long-term use.  Nonetheless, their normal operation can be compromised by the conditions of the 
gate; therefore, we will list some operations to keep the gate efficient. 

Warning:

 Non-specialized staff cannot operate the gate during maintenance. You are advised to cut the network power in order to avoid 

accidents or shocks.  If the power must be on for various inspections, you are advised to check and/or deactivate any possible control 
devices (remote controls, keyboards, etc…) except for the devise used by the maintenance operator. 

 

Routine maintenance 

Each of the following operations must be done when needed and in all cases at least every 6 months: 

Gate 

 

Lubricate the gate’s sliding wheels; 

 

Check the cleanliness and air-tightness of the rack. 

 

Automation System  

 

Check the operation of the safety devices (photo-cells, ribs, torque limiter) using the methods described by the suppliers  

 

Extraordinary Maintenance 

If special maintenance is required for mechanical parts, you are advised to send the gear motor out for 
repairs to be performed by the technicians at the manufacturer. 

 

Summary of Contents for QK E3000

Page 1: ...www quikoitaly com 230V 400V MOTOR FOR SLIDING GATES ERCOLE USE AND MAINTENANCE MANUAL QK E3000T QK E3000 V01_2011 ...

Page 2: ... MATERIALS FOR INSTALLATION 3 INSTALLING THE COUNTERPLATE 3 POSITIONING THE GEARMOTOR 4 INSTALLING THE RACK 4 FASTENING AND ADJUSTING OF THE END LIMIT SWITCHES 5 UNLOCKING THE MOTOR MANUALLY 5 ADJUSTING THE CLUTCH 5 GENERAL ADVICE 6 USE 6 MAINTENANCE 6 TYPICAL SYSTEM 7 DECLARATION OF COMPLIANCE 7 ...

Page 3: ...omated the gate becomes a machine and is therefore subjected to the rules of the Machinery Directive It is on the installer to verify its security WARNING Quiko Italy Sas is not liable for any damages to people animals or things due to unauthorized modifications alterations or betterments on its products by third parties QK E3000T POWER 400V THREE PHASE ABSORBED POWER 850W ABSORBED CURRENT 3 3A QK...

Page 4: ...end cams or runners 4 Nylon rack INSTALLING THE COUNTERPLATE Fig C Dig the foundations at least 15 cm deep Supply a protective cable sheath Attach it to the ground using concrete completely covering the foundation of the plate A Gate B Protective cable sheath C Foundation counter plate ...

Page 5: ...ed insert the screws to fasten to the counterplate or eventually the concrete Fig D INSTALLING THE RACK Fig E Fig E A Gear motor B Screws Once a hole has been made in the door fasten the rack to the gate with self threading screws based on the measurements listed in Figure F ...

Page 6: ... the end limit switches as in fig G each of them near an end of the rack By manually moving the door place the end limit switches so they activate the spring connected to the micro switch just before the mechanical stops at the end of the rail now tighten the screws UNLOCKING THE MOTOR MANUALLY Fig H Fig I ADJUSTING THE CLUTCH Fig L ...

Page 7: ...ly visible to keep out of the gate s range of action if it is moving Wait until it has stopped not to let children or animals play near the gate not to let children use the remote control or other operating devices to carry out routine maintenance in case of failure to turn off electricity and operate the gate manually only if it is possible and safe Refrain from touching the gate and call an auth...

Page 8: ...SELECTOR 4 FLASHING LIGHT 5 AERIAL RG59 6 PHOTOCELLS ON LITTLE COLUMNS 7 GATE STOPPERS 8 RAIL 9 RACK TYPICAL SYSTEM ELECTRICAL CABLES CROSS SECTION a 2x0 5 mm 2 b 4x0 5 mm 2 c 3x0 5 mm 2 d 3x1 mm 2 e 2x0 5 mm 2 f 4x0 5 mm 2 g 4x0 5 mm 2 h 2x0 5 mm 2 i 3x1 5 supply line ...

Page 9: ...ements of the regulations Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC and their amendments and modifications and with the regulations set forth by the National Legislative Body of the country in which the machinery is destined for use Via Seccalegno 19 36040 Sossano VI Italia Managing Director Luca Borinato Sossano 19 10 2011 ...

Page 10: ...related and or specific national technical regulations have been followed EN 12453 EN 12445 on Industrial Commercial and Residential Gates and Doors Safe Use of Motorized Doors Requirements and Classification Test Methods EN 12604 EN 12605 on Industrial Commercial and Residential Gates and Doors Mechanical Aspects Requirements and Classification Test Methods CEI 64 8 Electrical Systems Using Nomin...

Page 11: ...www quikoitaly com ...

Page 12: ...QUIKO ITALY Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...

Reviews: