Controls and Components

Units are supplied with a wireless remote controller, which communicates with the unit Microprocessor controller
The return air temperature sensor mounted on the unit then controls the unit operation
Heat Pump units require the defrost sensor connecting between the Outdoor & Indoor units prior to operation
Several modes of operation are available to the end user depending on the type of comfort required
All unit operating functions are controlled via the remote controller
Unit operating modes are : Auto, Cool, Dry, Fan and Heat (Heat Pump only)

Optional Controls and Components

Low Ambient Controller : ICM 326H must be used in Data Room or Commercial applications 

For a wiring diagram please contact Quietside or follow general diagram supplied with ICM Controller
Probe must be located in the fin pack or on a return bend that measures approx 100 DegF during normal 
operation

Condensate Pump : 

Field Installed Mini Pump, Quietside recommend the Aspen brand of Condensate

Pump, follow their wiring diagram recommendations.  This pump is installed externally to the unit

Follow Instructions, failure to follow instructions may cause 
possible malfunction and void any warranty

Step 1
Remove Indoor and Outdoor units from the carton/box

Indoor unit carton contains Remote Control, Batteries and 25ft Defrost Sensor interconnect wire (HP only) 
Ensure these are kept in a safe place during the installation process.  

Step 2 
Locate area to Install Indoor unit

Indoor unit must be located a minimum of 4ft from the floor and 4" from the ceiling
Choose an area where the wall is plumb and determine how to best to run the unit interconnects 

 4" from ceiling

               8" from wall

    8" from wall

Minimum 4ft from floor
Optimum 6ft plus from floor

Ensure no obstacles to Airflow are directly in front of the unit, for a minimum of 12ft for 9/12,000 Btu/h units
and 16ft for 18/24,000 Btu/h units
Do not install the Indoor unit units in areas exposed to high humidity (RH of 80% plus), direct sunlight and 
direct heat from stoves or other devices

Installation and Maintenance Manual

Unit Installation

Indoor Unit

Summary of Contents for QSCE-093

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ...manual 1 Check Rating Plate for correct system voltage before installing the unit Installing and operating a unit with the incorrect voltage may result in malfunction or other issues and will void th...

Page 16: ...t s below 65 DegF so a Low Ambient Head Pressure Controller See accessories is required as is a Crankcase Heater field supplied Residential Bedrooms Family Rooms etc These require ballpark sizing of a...

Page 17: ...ide recommend the Aspen brand of Condensate Pump follow their wiring diagram recommendations This pump is installed externally to the unit Follow Instructions failure to follow instructions may cause...

Page 18: ...ng the weight of the unit Use a level to ensure mounting bracket is leveled so condensate can drain properly Step 5 Prepare Unit Line Set Connections Rotate refrigerant line stubs set gently through 9...

Page 19: ...set between the Outdoor unit and the Indoor unit MUST have both refrigerant lines insulated as condensing device is located in the Outdoor unit Gently bend the line set stubs from the Indoor unit to...

Page 20: ......

Page 21: ...is required then cut the lead and extend it using 18 AWG thermostat wire Sensor is resistance based using 3 5V DC Defrost Sensor wire connection in Outdoor unit is accessed by removing top panel from...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: