Quietside QS09-VJ115 Installation Manual Download Page 7

27

Installation and Maintenance

Service Manual

Outlet

pipe

Drain hose

Drain hose

Tape

Outlet pipe

Insulating pipe

Torque wrench

Open-end 

wrench

Indoor pipe

Pipe

Union nut

Union nut

Pipe joint

Pipe

Hex nut diameter(inch) Tightening torque(N.m)

1/4"

15~20

3/8”

30~40

1/2”

45~55

5/8”

60~65

3/4”

70~75

Refer to the following table for wrench moment of force

:

Drain hose

Insulating pipe

(1) Add insulating pipe in the indoor drain hose in order to 
prevent condensation.
(2) The plastic expansion particles are not provided.
(As show in Fig.10)

Fig.5

Fig.6

Fig.7

Fig.8

Fig.9

Fig.10

Left

Rear left

Right

Rear right

Cut off

the hole

Left

Right

Fig.3

Fig.4

3. Install Wall-mounting Frame

(1) Choose the position of piping hole according to the direction 
of outlet pipe. The position of piping hole should be a little 
lower than the wall-mounted frame.(As show in Fig.1)

5. Connect the Pipe of Indoor Unit

(1) Aim the pipe joint at the corresponding bellmouth.(As show 
in Fig.5)
(2) Pretightening the union nut with hand.
(3) Adjust the torque force by referring to the following sheet. 
Place the open-end wrench on the pipe joint and place the 
torque wrench on the union nut. Tighten the union nut with 
torque wrench.(As show in Fig.6) 
(4) Wrap the indoor pipe and joint of connection pipe with 
insulating pipe, and then wrap it with tape.(As show in Fig.7)

6. Install Drain Hose

(1) Connect the drain hose to the outlet pipe of indoor unit.(As 
show in Fig.8)
(2) Bind the joint with tape.(As show in Fig.9)

4. Outlet pipe

(1) The pipe can be led out in the direction of right, rear right, 
left or rear left.(As show in Fig.3)

(2) When selecting leading out the pipe from left or right, please 
cut off the corresponding hole on the bottom case.(As show in 
Fig.4)

(2) Open a piping hole with the diameter of Φ55 on the selected 
outlet pipe position.In order to drain smoothly, slant the piping 
hole on the wall slightly downward to the outdoor side with the 
gradient of 5-10°.(As show in Fig.2)

(1) Pay attention to dust prevention and take relevant safety 
measures when opening the hole.
(2) The plastic expansion particles are not provided and should 
be bought locally.

Note:

Note:

5-10

°

Φ

55 

or Φ

70

Indoor

Outdoor

Fig.2

Φ2.2 inch

Fig.1

 

m

m

1

 

Ф55 mm 

Ф55 mm 

 m

m

1

Wall

Wall

Mark on the middle of it 

Gradienter 

Left 

Right 

(Rear piping hole) 

(Rear piping hole) 

Space  
to the  
wall 

above 

Space  
to the  
wall 

above 

Φ2.2 inch

Φ2.2 inch

Space 

to the 

wall 5ft. 

above

Space 

to the 

wall 5ft. 

above

Summary of Contents for QS09-VJ115

Page 1: ...QS09 VJ115 QS12 VJ115 QS09 VP115 QS12 VP115 Refrigerant R410A Model INSTALLATION MANUAL...

Page 2: ...condition must apply specialized circuit and prohibit share the same circuit with other appliances 3 The air conditioner should be installed in suitable location and ensure the power plug is touchabl...

Page 3: ...ng tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 T...

Page 4: ...east 0 5ft At least 0 5ft At least 0 5ft At least 8 2ft Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wa...

Page 5: ...or unit Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installat...

Page 6: ...ditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safety regulations 4 The appliance must be positioned so that the plug...

Page 7: ...e the torque wrench on the union nut Tighten the union nut with torque wrench As show in Fig 6 4 Wrap the indoor pipe and joint of connection pipe with insulating pipe and then wrap it with tape As sh...

Page 8: ...ower connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip connect the power connection wire to t...

Page 9: ...ve the cable crossing board 2 of right side plate for outdoor unit 2 Remove the wire clamps pass the power connection cord and power cord through the cable crossing board 1 to connect the terminal The...

Page 10: ...Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent 2 Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then conne...

Reviews: