All QuietCool models require regular 3 prongs, ground with 120 volt power supply. Plug electrical cord into receptacle. If 

using an extension cord be sure it is rated for at least 20 amps for the distance your cord is running. To be safe – make sure 

no  other  equipment,  such  as  a  radio  or  electrical  equipment,  is  plugged  into  the  same  circuit.  The  QuietCool  should  run 

smoothly on 20 amp, 120 volt, and 60 Hz circuit.  

 

4.2 Connecting the water supply 

Connect  standard  water  hose  to  female  fitting  on  the  right  side  of  your  QuietCool  (looking  at  the  fan  blade  side).  If  your 

water  pressure  is  above  60  pounds  per  square  inch  (p.s.i).  you  must  use  a  pressure  regulator  (which  can  be  found  at  your 

local hardware store). If you have purchased our optional QR60 gallon reservoir tank  – simply attach the garden hose from 

the tank to the cooler. 

Note:

 Do not connect to water source exceeding 60 p.s.i. – this can cause damage to your QuietCool. 

 

5.0  Operating procedures 

Back  your  QuietCool  unit  up  to  a  fresh  air  source 

such as an open door or window so the unit can pull 

in  fresh  air  from  the  outside.  Next,  make  sure  you 

have  a  natural  exhaust  at  the  opposite  end  of  the 

room, bay or building such as a window, door or bay 

door.  This  will  ensure  maximum  efficiency  from 

your unit. Finally make sure there are no obstructions 

between  your  QuietCool  and  the  people  /  area  you 

need to cool. 

 

5.1  Filling the units reservoir with water 

Once your water hose is connected, turn water on and 

fill  the  reservoir  with  water.  Listen  carefully.  You 

can  hear  water  filling  the  reservoir.  Check  your  water  connection  –  make  sure  there  is  no  dripping.  Once  the  reservoir  is 

filled with water the float valve will automatically shut off the water source.  When you no longer hear the water running – 

you know that the float valve is fully operational  (the water turns off automatically) and you are now ready to turn on the 

water pump. 

Warning! Do not run water pump without water in the reservoir.

 

 

5.2  Turn-on pump  

To turn-on the water pump - flip the toggle switch for the water pump to on. Switch is located on front side of unit. 

Warning! Do not run water pump without water in the reservoir

. The water pump will now begin pumping water to the 

top of the unit so that gravity will allow the water to run down the backside of unit inside and on the cooling pads. Once 

your QuietCool cooling pads are saturated – then, you are ready to turn fan on high and begin to feel the cooling effect from 

your new QuietCool. Note: After your cooling pads are broken in (typically takes 1 -2 weeks in operation) it will take less 

time to saturate pads for start-up. This is a good time to dump the old water – add ½ Evap-O-Matic Chemical Water 

Treatment tablet and refill with fresh water. (Simply remove a cooling pad to place tablet inside of water reservoir). 

 
5.4  Turn-on Fan 

 

Summary of Contents for QC18DVS

Page 1: ...he QC18DVS QuietCool Portable Evaporative Cooler QC18DVS QuietCool 18 Direct Drive Variable Speed with Deep Base Shown QC18D3 QuietCool 18 Direct Drive 3 Speed with Deep Base Optional Cover for storag...

Page 2: ...er voltage frequency configuration See manufacturer s label on cooler A ground fault circuit interrupter protected circuit is strongly recommended WARNING Check your units electric power cord for insu...

Page 3: ...Operating procedures 6 1 Turn on pump 6 2 Turn on fan 6 3 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7 2 Removing the cooling media 7 3 Daily maintenance 7 4 Periodic maintenance 7 5 Qui...

Page 4: ...me temperature air same humidity your QuietCool portable evaporative cooler takes that same existing air combines it with evaporating water which dramatically lowers the temperature immediately reliev...

Page 5: ...s between your QuietCool and the people area you need to cool 5 1 Filling the units reservoir with water Once your water hose is connected turn water on and fill the reservoir with water Listen carefu...

Page 6: ...cooling pads are thoroughly dry about 10 15 minutes Once your cooling pads are completely dry you may turn off fan Now unplug electricity to unit to avoid unnecessary shock Next using a 7 16 wrench r...

Page 7: ...ply follow instructions on the label You may want to consider a Water Stabilizer to remove harmful calcium scale build up and algae see section 9 0 Warning Do not run pump without water in the reservo...

Page 8: ...water filter pull out filter screen and clean Replace and try again Use Evapo O Matic Tablet or add a Water Stabilizer at the discharge side of the pump See Accessories section 9 0 Flush water from u...

Page 9: ...s scale and calcium deposits associated with hard water Adds life to vital cooler equipment increases cooling efficiency and ends swampy odors Treatment 1 2 tablet for18 units EPA registered protectio...

Page 10: ...er form QC18PUMP Replacement Pump for all 18 units Simply replace the new pump with the old pump List 81 00 each TR798 Float Valve for all 36 units Automatically adjusts water level in units reservoir...

Page 11: ...s water level TR798 List 16 00 each Inline filter Catches large debris in water line to cooling pads 12Filter List 23 00 each Replacement Casters Straight Swivel Wheel Sold in set of 4 QC18CK 4 Wheels...

Page 12: ...12 12 0 Wiring Diagrams for 18 unit...

Page 13: ...the defective product or part damages due to removal or any expenses incurred in shipping the product of part to or from Quietaire Cooling plant or the installation of the repaired or replaced produc...

Reviews: