READ ALL INSTRUCTIONS IN THIS GUIDE BEFORE INSTALLING YOUR QUIETCOOL

GETTING STARTED

 

STOP! 

Read the following pages before proceeding! The manufacturer is NOT responsible 

for faulty installation or product damages caused through failure to fully read this guide 

BEFORE attempting installation. 

GENERAL SAFETY INFORMATION

 

1. READ INSTRUCTIONS

 - All safety and operation instructions must be read.

2. RETAIN INSTRUCTIONS

 - The safety and operating instructions should be kept for future reference.

3. HEED WARNINGS

 - All warnings should be followed.

4. FOLLOW INSTRUCTIONS

 - All installation and operating instructions should be followed.

5. WATER

 - The QuietCool system should not be used near water. If you live in a very humid climate,  

    be sure to cover your damper box with insulation to reduce condensation.

6. HEAT

 - The QuietCool system should be situated away from heat sources.

7. DAMAGE REQUIRING SERVICE

 - Only qualified service personnel should service the QuietCool system.   

    The user should not attempt to service the product. 

8. AVOID BACKDRAFTS

 - Care should be taken to avoid backdrafting combustion appliances that are  

 

    installed in the conditioned space. Whole house fans are capable of pulling large quantities of air, from
    the home, particularly if not enough windows are open. This could easily backdraft gas appliances 
    located inside your home. Take care if you have gas appliances installed inside of your home.

!

!

TEMPLATE SIZES

The template size varies depending on which model of QuietCool fan you are installing:

QuietCool Fan Model

Template Size

Vertical Adapter Model

(Sold Separately)

QC TRI PRO-1.5X

14-1/4” x 14-1/4”

VA-1414

QC TRI PRO-2.5X

14-1/4” x 18-1/4”

VA-1418

QC TRI PRO-3.3X

14-1/4” x 22-1/4”

VA-1422

QC TRI PRO-4.8X & 5.5X

14-1/4” x 30-1/4”

VA-1430

QC TRI PRO-6.0X & 7.0X

14-1/4” x 36-1/4”

VA-1436

!

!

!!

WARNINGS

CAUTION: 

This unit has an unguarded impeller. Do not use 

in locations readily accessible to people or animals.

CAUTION: 

Do not operate any fan with a damaged cord or 

plug. Discard fan or return to an authorized service facility 

for examination and/or repair.

 

CAUTION: 

Do not run cord under carpeting. Do 

not cover cord with throw rugs, runners, or similar 

coverings. Do not route cord under furniture or 

appliances. Arrange cord away from traffic area 

and where it will not be tripped over.

!

!

Summary of Contents for QC TRI PRO-1.5X

Page 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE TRIDENT PRO X WHOLE HOUSE FAN...

Page 2: ...nts 7 GETTING STARTED IMPORTANT READ BEFORE INSTALL 8 3 INSTALLATION 10 3 1 Installing QuietCool 10 3 2 Installing Vertical Adapter 12 4 WIRING 13 4 1 Single Speed Wiring QC TRI PRO 1 5X 13 4 2 Two Sp...

Page 3: ...o a loud vacuum cleaner running The QuietCool system uses a cutting edge patented design to get our sound levels down to a respectable level Our fans suspend in the attic and use an acoustical duct th...

Page 4: ...arly evening is spent in the kitchen or family room area Assuming this to be true this is where you would want to start the cooling process Begin opening a few windows in the area you are going to be...

Page 5: ...healthier If you have any trouble installing or operating your new QuietCool whole house fan or for more tips on running the QuietCool please visit our website www QuietCoolSystems com or call us at...

Page 6: ...from potential injury or fan obstruction F HIGH PERFORMANCE ACOUSTICAL DUCTING Noise dampening technology with insulated ducting that is used to separate the Steel Housing from the living space G AIR...

Page 7: ...ould with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractors can add extra ventin...

Page 8: ...Care should be taken to avoid backdrafting combustion appliances that are installed in the conditioned space Whole house fans are capable of pulling large quantities of air from the home particularly...

Page 9: ...ST your QuietCool unit before installation using the included power cord If the fan does not work call us immediately SPECIAL INSTRUCTIONS TO CONTRACTORS 1 DO NOT take the Owner s Guide with you after...

Page 10: ...cut out the hole in the ceiling 4 Open and unpack your QuietCool fan TIP If your attic is very tight you may want to wire your QuietCool motor housing before bringing it into the attic Please follow t...

Page 11: ...s in place when you are screwing in the grille If you do not fasten the damper box to the drywall the damper box will not stay in place when attempting to screw in the grille 9 Remove ceiling grille a...

Page 12: ...side of the vertical adapter Place the vertical adapter with the T side up onto the damper box with the side that has only two flanges flush on the damper box 2 If you have studs spaced at 16 on cent...

Page 13: ...m wiring a dedicated circuit may be required NOTE Your fan came pre wired to a power cord for testing purposes before installation If you would like to hard wire the fan or it is required by your loca...

Page 14: ...rom the power cord Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure 4 1B 9 In...

Page 15: ...e green ground wire on the timer 3 Using the included wire nuts tie the black wire from the 2 wire power source to the black wire on the timer Tie the white neutral wire from the 2 wire power source t...

Page 16: ...d Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure D 9 Install the included r...

Page 17: ...or multi speed QuietCool fans on one single speed TWO SPEED CONTROLS TIMER HIGH LOW OFF SWITCH To control a multi speed QuietCool fan we recommend the 8 Hour Countdown Timer and a HIGH LOW OFF Switch...

Page 18: ...installed or by movement distortion cracking or settling of walls or the foundation of the building QC Manufacturing Inc reserves the right to discontinue or modify any of its products including witho...

Page 19: ...ny kind including any damage to the building its contents or any persons therein resulting from the breach of any warranty set forth herein unless exclusion of these types of damages are specifically...

Page 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 9 26 22...

Reviews: