QUIETCOOLSYSTEMS.COM
5
2.
Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub. Cap the yellow and red wires from the Hub.
3.
FOR TRIDENT AND CLASSIC MODELS:
Connect the red wire from the fan to the
blue wire on the Hub
FOR STEALTH AND ENERGY SAVER MODELS:
Connect the black wire from the
fan to the blue wire on the Hub
4.
Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
5.
Set the dip switch positions inside the Hub as shown in the diagram below.
6.
Power-on the Hub. The Power LED indicator will be lit.
7.
Press the Test button to make sure the fan works. The Test LED indicator will blink
once every two seconds indicating 1-speed and the fan will be on. Press the Test
button again and the fan should shut off and the LED will be off. If the fan doesn’t
operate as described in step 6, please check the dip switch postion.
Two Speed Wiring (for CL-2250 to 7000 and TRI PRO-2.5 to 7.0) (see Figure B)
1.
Using a wire nut, connect the black wire from the power cord to the black wire
from the Hub.
2.
Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3.
Connect the black wire from the fan to the blue wire on the Hub. Connect the red
wire from the fan to the red wire on the Hub. Cap the yellow wire from the Hub.
4.
Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER
PAIR
TEST
Set dip switches:
1 - ON
2 - OFF
3 - OFF
ON
1 2 3
Whole House Fan
Figure A