background image

12

QUIETCOOLSYSTEMS.COM

4. SYSTEM OPERATING INSTRUCTIONS

4.1  When to Run the QuietCool Whole House Fans

Anytime it is cooler outside than the inside of your home, the system will work effectively. In the summer this 
normally happens in the late afternoon to early evening, through to the next morning. We recommend running 
your fan through the evening. If you have a multi-speed fan, you will get the best cooling effect when you turn 
the fan on low after desired cooling occurs and let it run throughout the night.

4.2  Where to Start Cooling the Home

We recommend cooling the area where you are going to be spending the most time for the next few hours. 
For example, in most family situations, the early evening is spent in the kitchen or family room area. Assuming 
this to be true, this is where you would want to start the cooling process. Begin by opening a few windows in 
the area you are going to be spending your time and turn on all of your 

QuietCool 

fans at once, for maximum 

cooling. The cooler air outside will immediately begin to create a breeze in the home making you feel up to 
10 degrees cooler, instantly. Opening windows too wide or opening too many windows will lessen the cooling 
breeze you feel.

The breeze will flow through your home and make its way to each 

QuietCool

 you have in operation. 

As it gets later in the evening, and even cooler outside, you can begin to open windows in other rooms of your 
home, to prepare for bedtime. Then when it’s time for bed, you should close all the windows in your main living 
space, but leave the windows in your occupied bedrooms open. This will provide each room with a cool breeze 
as long as desired. If you are using an 8 hour timer, you can automate your fan and have it turn off when 
you anticipate it being comfortable for sleeping. If you have a 

QuietCool

 installed in each bedroom as we 

recommend, you can enjoy the breeze and your privacy with your door closed. 

4.3  Indoor Air Quality

You will want to ventilate your home on a very regular basis. Many studies show that the air inside the homes 
in the United States is more polluted than the air outside. This is generally true even in the smoggiest of 
cities. Your 

QuietCool

 system can greatly reduce this problem by bringing in fresh air and exhausting stale 

polluted air all year round.

 
If you have any trouble installing or operating your new 

QuietCool

 whole house fan, please visit our website 

at 

www.QuietCoolSystems.com

 for support or call us at 

951-325-6340

Quiet Cool is proudly designed and built in California.

Summary of Contents for CL-1500

Page 1: ...1 QUIETCOOLSYSTEMS COM SEE HEAR FEEL THE QUIETCOOL DIFFERENCE THE NATURAL CHOICE FOR ENERGY SAVINGS OWNER S GUIDE ORIGINAL CLASSIC LINE...

Page 2: ...ith insulation to reduce condensation 6 Heat The QuietCool system should be situated away from heat sources 7 Damage Requiring Service Only qualified service personnel should service the QuietCool sys...

Page 3: ...vacuum cleaner running In contrast our QuietCool whole house fans average at just around 45 dB that s equivalent to quiet conversation The QuietCool system uses a cutting edge patented design to get...

Page 4: ...RTANT 1 SQUARE FOOT OF NET FREE VENTING PER 750 CFM REQUIRED VENTILATION 1 SQ FT FOR EACH 750 CFM Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70 Eave...

Page 5: ...e exact location for each fan Take the cardboard cut out template and a small screwdriver with you Make sure the template fits between the framing The rough opening size varies depending on which mode...

Page 6: ...place mark its outline with a pencil NOTE Repeat these steps at each location 4 Using a drywall saw or similar device cut out the hole in the ceiling NOTE Repeat these steps at each location 5 Open a...

Page 7: ...ither the drywall or the joist in the attic While holding it in place install a 1 3 8 drywall screw through the drywall into the flange of damper box on each side to temporarily hold the box in place...

Page 8: ...from the home and particularly if not enough windows are open This could easily back draft gas appliances located inside your home 3 WIRING NOTE Wiring Diagrams are for examples only and wiring shoul...

Page 9: ...g up the handy box Take off the wire nuts within the handy box Unscrew the green ground wire Detach the green ground wire from the power cord Remove the power cord Re attach the ground screw and wire...

Page 10: ...Using the included wire nuts tie the black wire from the 2 wire power source to the black wire on the timer Tie the white neutral wire from the 2 wire power source to the white neutral wire on the ti...

Page 11: ...Whole House Fan Tie All Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD 14 3 Wire OFF Power Source Black Tied Together with Black Red Switch Leg High Low Two Speed Wiring...

Page 12: ...head Open up the handy box and take off all the wire nuts Unscrew the green ground wire and detach the green ground wire from the power cord Remove the power cord Reattch the green ground wire to the...

Page 13: ...gether with Black Red Switch Leg Off On On Off Two Speed Wiring Tie Common Wires Together Black Wires Whole House Fans Tie All Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR H...

Page 14: ...ndows will lessen the cooling breeze you feel The breeze will flow through your home and make its way to each QuietCool you have in operation As it gets later in the evening and even cooler outside yo...

Page 15: ...ranty contact the dealer where you purchased the equipment If you are unable to find or reach your dealer contact Customer Service at QC Manufacturing Inc at the address below E Please register your p...

Page 16: ...14 1 888 QUIETCOOL 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California...