6.  Post-Installation Tests 

 

6.1

 EMI / RFI Test Procedure and Log

 

After installation of the Quiet Power unit and confirmation of normal operation on aircraft battery 
power, an EMI / RFI check may be performed in accordance with the following ground test 
procedure.  Note that this device has been qualified to DO-160G Section 21.0   Emission of Radio 
Frequency Energy, Category M (Cockpit equipment). Consult AC 43.13-1B Section 8, Paragraph 
11-107 or other regulatory guidance to confirm compliance with applicable regulations. Should the 
installer determine that EMI / RFI testing is not required, notate the test log. 

6.1.1

  VOR/LOC/ILS (if equipped) 

Verify normal operation of the Navigation receiver(s) and VOR indicator(s) and audio output 
while tuning the receiver from 108.00 MHz to 117 MHz at 1 MHz increments. Turn the Quiet 
Power unit off and on at 108.00, 112.00 and 116.00 and note whether any anomalies exist in 
the VOR/LOC/ILS indicator or whether there is interference detected in the received audio. 

 
 

Test 

Interference / 

Anomalies 

Yes / No 

Sweep Results – 108.00  to 117.00 mHz 
 

 

 

Anomalies 

108 mHz 

 

Anomalies 

112 mHz 

 

Anomalies 

116 mHz 

 

 
Comments: 

 _____________________________________________________________________________ 

_______________________________________________________ 

6.1.2

  Marker Beacon (if equipped)  

Turn on the Marker Beacon receiver and set it to its most sensitive receive configuration. 
Confirm that the Marker Beacon receiver does not trigger or break squelch when the Quiet 
Power unit is turned on and off. 

Test 

MB Indication / 

Audio Output 

Yes / No 

Quiet Power unit turned on and off  

 

 

Comments: 

 _____________________________________________________________________________ 

_______________________________________________________ 

   

 

Summary of Contents for QP100 Series

Page 1: ...Installation and Operation Manual Quiet Power Dual USB Charger QP100 Series Document Part Number 98 790002 Revision 3 June 2015...

Page 2: ...ES 8 4 3 1 Auxiliary Charger Panel Connector 8 5 DOCUMENTATION 9 5 1 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS 9 5 2 LOGBOOK ENTRY 10 6 POST INSTALLATION TESTS 11 6 1 EMI RFI TEST PROCEDURE AND LOG 11...

Page 3: ...pply to i damage caused by accident abuse misuse water flood fire or other acts of nature or external causes ii damage caused by service performed by another party iii cosmetic damage such as scratche...

Page 4: ...24 2014 1 Original Release 7 30 2014 2 Corrected wiring reference in section 4 Added available models options Section 1 4 1 7 2015 3 Added circuit breaker value table in Appendix B revised mechanical...

Page 5: ...n the top connector and 1 amp on the bottom connector A method referred to as analog negotiation is used to signal the PED as to the available power An optional auxiliary charging port is available on...

Page 6: ...eep Weight 3 5 oz 1 3 2 Electrical Input Voltage Range 10 volts to 36 volts D C QP100 QP102 or 13 2 to 36 volts D C QP103 QP104 Input Current 5 amps absolute maximum 1 2 5 amps average at rated load E...

Page 7: ...hole through the instrument panel and two mounting screw holes Refer to Section 7 3 Appendix C Mechanical Drawings for detailed panel information You may also install the device in a standard 2 or 3 i...

Page 8: ...1 Auxiliary Charger Panel Connector The auxiliary charger port supplies power to the auxiliary device through an optional panel connector and cable assembly Power from the main power unit is supplied...

Page 9: ...jack 5 5mm ID 2 5mm Pin Dia and a 4 1 3 M cable consisting of a mating panel plug 4 power cord and mating plug male per the following table Part Number Model Mating Plug Sample Application 66 790003 Q...

Page 10: ...ntry Complete an aircraft airframe logbook entry detailing the installation and post installation tests performed Note the tests performed by referencing Section 6 Post Installation Tests e g Tested t...

Page 11: ...tput while tuning the receiver from 108 00 MHz to 117 MHz at 1 MHz increments Turn the Quiet Power unit off and on at 108 00 112 00 and 116 00 and note whether any anomalies exist in the VOR LOC ILS i...

Page 12: ...r unit powered off Check each receiver for interference at 1 MHz increments from 118 00 to 136 00 MHz In the table below place a checkmark in the Interference column if interference is noted at the de...

Page 13: ...t Power unit is supplying power to the device Tests performed by _______________________________________________________________ Name print ____________________________________________________________...

Page 14: ...Fluids Susceptibility X Section 12 0 Sand and Dust X Section 13 0 Fungus Resistance X Section 14 0 Salt Spray X Section 15 0 Magnetic Effect X Section 16 0 Power Input B XX Section 17 0 Voltage Spike...

Page 15: ...liary power All variants of the dual USB connector version including those with auxiliary power ports utilize the same protection device rating Aircraft Bus Voltage Protection Device Rating 14 Volts 3...

Page 16: ...nual P N 98 790002 Rev 3 Page 16 7 3 Appendix C Mechanical Drawings 7 3 1 Panel Cutout Direct Panel Mount Two mounting methods are supported mounting with 6 32 screws or 4 40 screws 6 32 screws are re...

Page 17: ...Quiet Power USB Charger Installation and Operation Manual P N 98 790002 Rev 3 Page 17 Figure 3 Panel Cutout 4 40 Mounting Screws...

Page 18: ...Quiet Power USB Charger Installation and Operation Manual P N 98 790002 Rev 3 Page 18 7 3 2 2 Panel Mount Adapter Plate...

Page 19: ...Quiet Power USB Charger Installation and Operation Manual P N 98 790002 Rev 3 Page 19 7 3 3 3 Panel Mount Adapter Plate...

Reviews: