Quicksilver 675OP— Electrical Systems
30
1.
DC Electrical System
The DC electrical system is powered by a single battery, and is kept charged by the engine driven
alternator.
2.
Battery
Quicksilver® recommends AGM type starting or a deep cycle battery for you boat. The battery must
meet the minimum capacity required by the engine manufacturer. Refer to your engine owner’s
manual for exact battery requirements.
To remove the battery cables:
1.
Turn off all items drawing power from the battery.
2.
Turn the battery switch to the OFF position.
3.
Remove the negative cable first, then the positive cable.
To replace the cables, install the positive cable first, then the negative cable.
3.
Battery Box
The battery box, located in the aft bilge, houses the battery. This box can be accessed via the hatch
located in the port aft lounge storage tub. The battery can be installed or removed by loosening the
strap and removing the lid on the battery box. It should always be installed and secured within the
battery box installed on your boat. This will ensure that the battery will not move around while the
boat is underway.
4.
Battery Switch
Your vessel is equipped with a battery switch to control the delivery of DC power from the battery.
The battery switch panel is located in the aft lounge storage tub. When you turn the battery switch to
the ON position, power is provided from the battery to the entire boat. To turn on power, rotate the
switch clockwise 90 degrees to the ON position.
Never use an open flame in the battery storage area. Avoid
striking sparks in the battery area.
Always disconnect the battery before doing any work on the
electrical system. Never turn off the battery switches or
disconnect the battery cables while the engines are running.
The bilge pump and stereo memory still draws power from
the battery, even if the switch is set to OFF. This is especially
important for the bilge pump, so that it can operate
anytime excess fluid accumulates in the bilge, which can
occur when the boat is docked and unattended.
Never work on the electrical system while the system is
energized. Never leave the craft unattended with the
electrical system energized.
Battery Switch Operation
OFF Position
ON Position