![Quick SBC 1100 NRG+ FR Manual Of Installation And Use Download Page 21](http://html1.mh-extra.com/html/quick/sbc-1100-nrg-fr/sbc-1100-nrg-fr_manual-of-installation-and-use_3649710021.webp)
21
EN
SBC NRG
+
HIGH REV001B
INSTALLATION
BATTERY TEMPERATURE SENSOR
A temperature sensor for the batteries (KTBRJ) can be connected to the RJ11 socket.
BATTERY CHARGER’S SIMPLIFIED STATUS
On pin 4 of the RJ45 CAN OUT socket, a signal which indicates the operating status of the battery charger (presence or
absence of problems) is located (Fig. 4).
CAN OUT
4
5
FIG. 4
BATTERY
12V - 24V
KTBRJ
TEMPERATURE SENSOR
BATTERY
SENSOR CONNECTOR
BATTERY TYPE SELECTION
Select the type of battery to be charged by turning the selector on the front panel of the battery charger.
NUMBER
BATTERY TYPE
0*
EL open
1
EL sealed
2
GEL
3
AGM
4
Optima
®
5
Li-lon
6
RESERVED
7
RESERVED
8
RESERVED
9
RESERVED
WARNING:
select the battery type only when the battery charger is switched off.
WARNING
: in case a KTB4N interface (optional, with one or more sensors) is connected, the KTBRJ sensor
connected to the RJ11 socket will be automatically disabled.
Refer to the table below to select the type of batteries you want to charge:
3
2
* Factory setting
PIN 4 CAN OUT
CONNECTION
STATE
HIGH IMPEDANCE
Battery charger switched off or presence
of problems requiring manual reset.
≃
+ 13,
5
Vdc
Battery charger switched on and absence
of any problem requiring manual reset.