USER MANUAL
18
We recommend using the 191/192 thermometer for measuring the
tip temperature.
If the soldering station is locked by password, it will not be able to
calibrate the tip temperature and you must input the right
password.
2.8.
Tip care and maintenance
Select a Correct Tip
1.
Select a tip that maximizes contact area between the tip and solder
joint. Maximizing contact area gives the most efficient heat transfer,
allowing operators to produce high quality solder joints quickly.
2.
Select a tip that allows good access to the solder joint. Shorter tip
lengths allow more precise control. Longer or angled may be needed
for soldering densely populated boards.
2.9.
Error Messages
Various error messages will be displayed when there is something wrong with
the unit.
Sensor broken
:
sensor open away
Handle type
:
handle type wrong
NO handle:
handle is not insert
sensor shorten
:
sensor short circuit
heater shorten
:
heater short circuit