14 

2. Press “

or

”key to select address, the address range is 01-99 and the 

default address is01.   

3. Press “

” key to move the cursor to the Clear indicator and press “

or

” 

to  select  baud  rate,  the  baud  rate  is  9600,19200,38400  and  115200,  the 

default baud rate is 38400.   

4. Press “SET” key two times to save and press “BACK” to return. 

5.3.6 Language Menu 

  Figure5-3-6-1 

1.  In  the  Language  Menu  (see  Figure5-3-6-1),  user  press  “

or

”key  to 

select language.   

2. Press “SET” key two times to save and press “BACK” to return. 

NOTE: Only “

简体

” , “

繁体

”and “English” three languages supplied! 

Summary of Contents for QUICK6102A2

Page 1: ...QUICK6102A2 Fume Purifying Filtering System Instruction Manual...

Page 2: ...2 Thank you for purchasing our equipment please read this manual carefully before using it make sure you understand its capabilities and limitations Keep this manual handy for future reference...

Page 3: ...ion 7 5 1 Turn ON OFF Procedure 8 5 1 1 Turn ON Procedure 8 5 1 2 Turn OFF Procedure 8 5 2 Access Menu 8 5 3 Set menu 10 5 3 1 P Filter Flow Menu 10 5 3 2 M Filter Flow Menu 11 5 3 3 C Filter Flow Men...

Page 4: ...4 6 1 Alarm Message 15 6 2 Parts maintenance and changeable 17 6 3 Part Name 18...

Page 5: ...maintain will increase durability and performance Use original spare parts from QUICK to replace defective ones Do not use or store this product where children can reach Chapter 2 Introduction The un...

Page 6: ...asy to install and working station clean and tidy 2 Triple filters design remove hazardous substances to ensure health And the filters can be replaced separately 3 Circulate air filter type avoid indo...

Page 7: ...0mm Stationary Pressure 2400Pa Noise 65dB Dimension 470mm 230mm 500mm Weight 15 5Kg Note Ensure that your power supply data agrees with the information on the nameplate of the machine Chapter 5 Operat...

Page 8: ...ect the unit is in ON states when it is powered on 5 1 2 Turn OFF Procedure 1 Press SET key two times to save parameters 2 Press ON OFF key in the main menu to OFF the unit 3 Disassemble the handle bo...

Page 9: ...ord is 000 press SET key to confirm after enter password Press the key once to increase the value by one digit press and hold it to continuously increase Press the key once to decrease the value by on...

Page 10: ...omatically when you enter the right password see figure 5 3 1 User can press or key to select required item and press SET key to access menu A5 3 1 P Filter Flow Menu Figure5 3 1 1 1 In the P Filter F...

Page 11: ...S mode can reset the limit volume 5 3 2 M Filter Flow Menu Figure5 3 2 1 1 In the M Filter Flow Menu see Figure5 3 2 1 user press or key to move cursor to required item 2 Press or key to adjust the M...

Page 12: ...ss or key to move cursor to required item 2 Press or key to adjust the C Filter limit volume the range is 0 999km 3 Press key to move the cursor to the Clear indicator and press or to select 4 Press S...

Page 13: ...1 user press or key to select pipe diameter 2 Press SET key two times to save and press BACK to return NOTE Only 75 and 25 two pipe diameter supplied 5 3 5 Communication Menu Figure5 3 5 1 1 In the c...

Page 14: ...ct baud rate the baud rate is 9600 19200 38400 and 115200 the default baud rate is 38400 4 Press SET key two times to save and press BACK to return 5 3 6 Language Menu Figure5 3 6 1 1 In the Language...

Page 15: ...e cursor to required digit 3 Press SET key to confirm after entering new password once 4 Enter the same password in the Confirm Password area 5 Press SET key two times to save and press BACK to return...

Page 16: ...od Turn off the unit and plug the power cord Remove the top component check the filter and air inlet for dirt NOTE If has please remove it Check the motor circuit NOTE If you have any other problem pl...

Page 17: ...d set side Remove the damaged primary filter medium filter chemical filter Put the new filter as following 6 3 Part Name 6 2 Daily Check 1 The unit air inlet and handle box keep clean 2 Replace filter...

Page 18: ...Name Parts name 1 Hasp button 2 Unit case 3 Bottom seal rubber strip 4 Chemical filter C Filter 5 Medium filter M Filter 6 Primary filter P Filter 7 Top seal rubber strip 8 Net for isolation dirt 9 To...

Page 19: ...19...

Page 20: ...QUICK INTELLIGENT EQUIPMENT CO LTD ADD NO 11 FengXiang Road Wujin High Tech Industrial Development Zone Jiangsu China TEL 86 519 86225678 FAX 86 519 86558599 POSTCODE 213167 WEBSITE www quick global c...

Reviews: