USER MANUAL
6
2.5.3 System settings
Press the SYS key to open the settings menu.
The key must be pressed for 3 seconds.
Enter Password is displayed.
The default password is 0000. If the password is
entered correctly and confirmed with SYS, the
Setup menu is displayed:
2.5.3.1 Setting the maximum air flow rate
The individual filters can be selected with SET. In the following menu
the maximum air flow rate can be entered or changed behind Limit.
In this menu the counter can also be reset by switching from NO to
YES when Clear is pressed.
2.5.3.2 Changing the suction arm diameter
In the menu item Pipe Diameter the diameter of the extraction arm can
be selected using the keys. You can choose between 25mm and 75mm.
A change must be confirmed with SET.
NOTE: For the diameters 75mm and 50mm please select 75 in the
menu. For the diameter 25mm please select 25
2.5.3.3 Changing the Communication Address
In the menu item Communication, you can change the address and the
baud rate. Use the keys to select the menu item and the keys to
change the value. A change must be confirmed with SET.