Quick BK2 Series Installation And User Manual Download Page 6

BK2

EN

2

3

1

6

INSTALLATION AND USER'S MANUAL - QUICK BK 

Series

 

WATER 

 

HEATER

 - REV000A

4.0 - Installation requirements

The water heater must be installed in a dry and well-ventilated place. This precaution is necessary, even if the 

water heater is made of materials resistant to the marine environment, due to the presence of electrical devices 

(in models equipped with them). In addition, installation in an unventilated place may cause condensation; 

condensation may be mistaken for a false leak.

4.1 - Installation procedure

A - 

Apply the brackets to the tank (1).

B - 

Fix the water heater to a flat surface as shown in figure 1 using supports suitable for the weight of the water 

heater and the type of surface available for installation.

WARNING:

 the weight of the water heater indicated in the technical specifications refers to empty 

equipment. For the weight when fully loaded, add the weight of the mass of water filled in the 

equipment to the weight when empty (1 litre of water corresponds to approximately 1 kg. / 2.2 lb).

C - 

Make the hydraulic connections for the tap hot water input and output and the engine cooling circuit to the heat 

exchanger (in models featuring it) as shown in figure 2. The connection between the engine cooling circuit and the 

water heater exchanger should be as short as possible.

WARNING:

 the overpressure release pipe must be positioned on a continuous downward slope and 

in a place protected from ice formation. 

WARNING:

 water may drip from the overpressure release pipe; leave this pipe open so that it can 

drain the water in the atmosphere.

WARNING:

 use Loctite 243, 577 or Teflon when installing the fittings. 

Check that there are no water leaks.

4.2 - Use

WARNING:

 follow the engine manufacturer’s instructions to withdraw the coolant to be sent to the 

water heater exchanger.

• Position the stub pipe (2) of the valve (1) securing it with the clamp (3). Position it in 

such a way that any spillage of water will not damage other objects.

• Open the hot water taps of the washbasins and start the water pump. This allows 

the air in the water heater and in the pipes to flow out. Close the taps as soon as only 

water starts to flow out.

• 

Check that there is no leakage from the fittings.

4.2.0 - Power supply of the equipment

For connections to the AC network, see the wiring diagram on page 8. Before supplying power to the water heater, 

make sure that its operating voltage corresponds to that supplied by the AC network.

A double pole switch must be installed in the electrical system to turn the equipment on and off and a fuse suitable 

for its absorption. The insulation material between the contacts of the connections to the AC network must be at 

least 3 mm. Connections to the AC network must be made in accordance with the national standards on electrical 

systems.

Before connecting the equipment, make sure that cables are not live.

Never switch on the electric element if the water heater is NOT filled with water, otherwise the 

heating element could be irreversibly damaged.

4 - Installation / Use

Summary of Contents for BK2 Series

Page 1: ...EN INSTALLATION AND USER S MANUAL BK2 WATER HEATER BK2 SERIES WATER HEATER WITH SINGLE AND DOUBLE ELECTRIC ELEMENTS 160 200 REV 001A...

Page 2: ......

Page 3: ...supply and material included in the package 5 3 Introduction 5 3 0 Important notes 5 3 1 Precautions 5 3 2 Precautions for the installer 5 4 Installation Use 6 4 0 Installation requirements 6 4 1 Inst...

Page 4: ...cing hot water even with the electric element complete with adjustable and safety thermostat in models equipped with it Relief non return valve that allows the water heater to drain the water when not...

Page 5: ...on Quick shall not be held liable for direct or indirect damage caused by improper use of the product Before connecting the equipment make sure that cables are not live This equipment is not intended...

Page 6: ...protected from ice formation WARNING water may drip from the overpressure release pipe leave this pipe open so that it can drain the water in the atmosphere WARNING use Loctite 243 577 or Teflon when...

Page 7: ...000A FIG 1 FIG 2 HOT TAP WATER OUTPUT HOT TAP WATER OUTPUT HOT TAP WATER OUTPUT vertical installation only HOT TAP WATER OUTPUT COLD TAP WATER INPUT COLD TAP WATER INPUT COLD TAP WATER INPUT TAP WATER...

Page 8: ...the protection cover 4 to reach the thermostat 5 fig 3 Use a screwdriver to turn the thermostat knob and set the desired temperature value fig 4 Refit the protection cover 4 Restore the power supply F...

Page 9: ...S MANUAL QUICK BK Series WATER HEATER REV000A SINGLE PHASE WIRING DIAGRAM SINGLE PHASE 2000 WATT CONNECTION THREE PHASE WIRING DIAGRAM THREE PHASE 4000 WATT CONNECTION SINGLE ELECTRIC ELEMENT DOUBLE E...

Page 10: ...nual reset device WARNING if the overtemperature safety device is triggered repeatedly during the use of the water heater contact a quick service centre WARNING if the power cable is damaged have it r...

Page 11: ...erials some can be recycled and others must be suitably disposed of enquire about the recycling or disposal systems provided for by local regulations for this product category Some parts of the produc...

Page 12: ...BK2 WATER HEATER 160 200 Product serial number QUICK S p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com REV 001A...