background image

BK2

EN

A

4

5

10

INSTALLATION AND USER'S MANUAL - QUICK BK 

Series

 

WATER 

 

HEATER

 - REV000A

WARNING: Quick

®

 water heaters are equipped with a double thermostat with manual reset that cuts 

off the power supply in the event of too a high water temperature.

If this condition occurs, proceed as follows:

PROCEDURE for SINGLE-PHASE manual reset:

• Interrupt the power supply

• 

Remove the protection cover (4, fig.6) to reach the thermostat.

• 

Use a screwdriver to turn the thermostat knob 5 (fig. 7) and set the maximum temperature value.

• 

Press the reset button on the double thermostat (fig.7).

• 

Use a screwdriver to turn the thermostat knob (fig.7) and set the desired temperature value.

• 

Refit the protection cover (4).

• Restore the power supply.

ELECTRIC 
ELEMENT

THREE-PHASE

: The three-phase thermostat is provided with a manual reset device.

WARNING:

 if the overtemperature safety device is triggered repeatedly during the use of the water 

heater, contact a quick

®

 service centre.

WARNING:

 if the power cable is damaged, have it replaced at a Quick

®

 service centre. To avoid 

accidents, the equipment must only be opened by authorised personnel. The warranty will be void if 

the equipment is opened by unauthorised personnel.

It is advisable to check the magnesium anode (A) every 12 months. Replace it if deteriorated. This 

simple preventive maintenance guarantees a long equipment life over time.

During the cold season, if the water heater is not in use, it is advisable to empty it using the valve lever (9). This is to 

avoid damage caused by frost.

Periodically check the hydraulic system fittings for leaks; check the tightness of the fastening screws and replace 

them if they are worn out or corroded.

Periodically check the efficiency of the electrical system.

TEMPERATURE 
SETTING KNOB

RESET 
BUTTON

FIG.6

FIG.7

6 - Maintenance

Summary of Contents for BK 160

Page 1: ...EN INSTALLATION AND USER S MANUAL BK2 WATER HEATER BK2 SERIES WATER HEATER WITH SINGLE AND DOUBLE ELECTRIC ELEMENTS 160 200 REV 001A...

Page 2: ......

Page 3: ...supply and material included in the package 5 3 Introduction 5 3 0 Important notes 5 3 1 Precautions 5 3 2 Precautions for the installer 5 4 Installation Use 6 4 0 Installation requirements 6 4 1 Inst...

Page 4: ...cing hot water even with the electric element complete with adjustable and safety thermostat in models equipped with it Relief non return valve that allows the water heater to drain the water when not...

Page 5: ...on Quick shall not be held liable for direct or indirect damage caused by improper use of the product Before connecting the equipment make sure that cables are not live This equipment is not intended...

Page 6: ...protected from ice formation WARNING water may drip from the overpressure release pipe leave this pipe open so that it can drain the water in the atmosphere WARNING use Loctite 243 577 or Teflon when...

Page 7: ...000A FIG 1 FIG 2 HOT TAP WATER OUTPUT HOT TAP WATER OUTPUT HOT TAP WATER OUTPUT vertical installation only HOT TAP WATER OUTPUT COLD TAP WATER INPUT COLD TAP WATER INPUT COLD TAP WATER INPUT TAP WATER...

Page 8: ...the protection cover 4 to reach the thermostat 5 fig 3 Use a screwdriver to turn the thermostat knob and set the desired temperature value fig 4 Refit the protection cover 4 Restore the power supply F...

Page 9: ...S MANUAL QUICK BK Series WATER HEATER REV000A SINGLE PHASE WIRING DIAGRAM SINGLE PHASE 2000 WATT CONNECTION THREE PHASE WIRING DIAGRAM THREE PHASE 4000 WATT CONNECTION SINGLE ELECTRIC ELEMENT DOUBLE E...

Page 10: ...nual reset device WARNING if the overtemperature safety device is triggered repeatedly during the use of the water heater contact a quick service centre WARNING if the power cable is damaged have it r...

Page 11: ...erials some can be recycled and others must be suitably disposed of enquire about the recycling or disposal systems provided for by local regulations for this product category Some parts of the produc...

Page 12: ...BK2 WATER HEATER 160 200 Product serial number QUICK S p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com REV 001A...