INSTALLATION
AFR 700/1000/1400W - REV009B
GB
WARNING:
before wiring up, be sure the electrical cables are not live.
BEFORE USING THE WINDLASS READ THESE INSTRUCTIONS CAREFULLY.
IF IN DOUBT, CONTACT YOUR NEAREST “QUICK
®
” DEALER.
WARNING:
the Quick
®
windlasses are designed to weigh the anchor.
Do not use the equipment for other purpo-
ses.
Quick
®
shall not be held responsible for damage to equipment and/or personal injury, caused by a faulty use
of the equipment.
The windlass is not designed for the loads that might occur in extreme weather conditions (storms).
Always deactivate the windlass when not in use.
Check that there are no swimmers nearby before dropping
anchor.
The splice between the rope and the chain must be tightly woven for the rope to slide easily into the gypsy
shape. For any problem or request, feel free to contact Quick
®
Technical Service.
For improved safety we recom-
mend installing at least two anchor windlass controls in case one is accidentally damaged.
We recommend the use of the Quick
®
hydraulic-magnetic switch as the motor safety switch.
Secure the chain with a further device before starting the navigation.
The contactor unit or reversing contactor unit must be installed in a point protected from accidental water contact.
THE PACKAGE CONTAINS:
windlass (on deck unit + motorgearbox) - contactor unit - base gasket - drill template - handle
- bolts and screws (for assembly) - user’s manual - conditions of warranty.
TOOLS REQUIRED FOR INSTALLATION:
drill and drill bits: Ø 9 mm (23/64") and Ø 11 mm (7/16") - Ø 53 mm (2"1/16) and
Ø 70 mm (2”3/4) hollow mill; hexagonal wrenche: 13 mm.
“QUICK
®
”ACCESSORIES RECOMMENDED:
anchoring RL control board (mod. 800) - Waterproof hand helds R/C (mod.
HRC1002) - Foot switch (mod. 900) - Hydraulic-magnetic circuit breaker - Anchor chain counter (mod. CHC1102M and
CHC1202M) - Radio control (mod. 1302,1352; 02, 302).
INSTALLATION REQUIREMENTS:
the windlass must be positioned with the gypsy aligned with the bow roller. Ensure that
the upper and lower surfaces of the deck are as parallel as possible. If this is not the case, compensate the difference appro-
priately (a lack of parallelism could result in a loss of motor power). The deck thickness must be included among the figures
listed in the table. In cases of other thicknesses it is necessary to consult a Quick
®
retailer. There must be no obstacles under
deck to the passage of cables, rope and chain; lack of depth of the peak could cause jamming.
FITTING PROCEDURE:
when the ideal position has been established, drill four holes using the drilling template provided.
Remove excess material from the chain passage, refine and flatten with a specialized product (marine paint, gel coat or 2 pack
epoxy) to assure free passage for both rope and chain. Position the upper section, inserting the gasket between the deck and
the base and connect the lower section to the assembly, inserting the shaft into the reduction unit. Fix the windlass by screw-