8

3) Enter the right password to enter the parameter setting menu.

Enter the initial password

1) The window displays “--” and the left hundred-digit flashes. At this time, the
hundred-digit number can be adjusted (you can enter the initial password

.

2) Input the initial password: Adjust the middle knob to change the hundred-digit number;
press “▲” key to move the digits and then ten-digit number began to flash, indicating that
it can be set in the same way as before. After the single-digit number is set, hold down the
“▲” and “▼” keys at the same time to confirm it.
3)

If the first password is wrong:

then directly enter the second password, and

the input method is same as the first time. (There are two chances of password input. If the
first password input is wrong, you can directly enter the second input.

4)

If the password entered twice is wrong

: the window will show “ERR”, and then

directly enter the main interface.
5)

If the first or the second password is correct

: then directly enter the parameter

settings, and the window shows “-1-”.

9.Parameter Setup

1) The password is entered correctly to access the parameter menu, and the sequence of
changes is shown in the following figure.

2) Click “▲” or “▼” button, select parameter menu-1, and return to the main interface
directly; after selecting parameter menu-2, press “▲” and “▼” buttons at the same time
to enter the new password setting.

Summary of Contents for 959D+

Page 1: ...QUICK 959D SMD REWORK STATION Instruction Manual Thank you for purchasing our products Please keep the instruction manual properly for future reference...

Page 2: ...utton Descriptions 5 5 4 Main Menu 5 6 Installation and Connection 6 6 1 Installation 6 6 2 Connection 6 7 Operation 7 8 Password Setup 7 9 Parameter Setup 8 10 New Password Setup 9 11 Temperature Cal...

Page 3: ...he product WARNING Products should be used away from magnetic field Do not place the product where the surface is vibrated or subject to shocks Do not install the product where it maybe wet Do not use...

Page 4: ...small or large air volume heater 3 Product Features Closed loop sensor microcomputer control temperature with high power and rapid temperature heat Air volume adjustable digital display and easy to ad...

Page 5: ...Display LCD Power 500W Max 580W Max Input voltage 110V AC 220V AC Temperature range 100 500 Air volume 1 100 Level Adjustable Airflow 40L min Max Dimensions L W H 110 180 151mm Weight About 1 6 Kg 5...

Page 6: ...4 5 2 Part Descriptions...

Page 7: ...annel numbers 2 Press and hold the Channel button to store the airflow and temperature of the current Channel 1 Temperature regulation 2 Press and hold buttons simultaneously to enter the temperature...

Page 8: ...ace the mounting hole of the handle holder on the two screw holes on the product and install two screws and tighten them 3 Install the handle holder and put the handle on the holder then check whether...

Page 9: ...to select Channel 1 Channel 2 Channel 3 respectively Long press the Channel button to store the parameters of the current Channel Sleeping Place the handle on the holder to cool The station will enter...

Page 10: ...is wrong then directly enter the second password and the input method is same as the first time There are two chances of password input If the first password input is wrong you can directly enter the...

Page 11: ...sword setting is not successful Return to the parameter setting and the password remains unchanged If the same number is entered twice the window will show OK which means the password is set successfu...

Page 12: ...ndle 4 Remove the orange and yellow cables connected in the Heater 5 Remove a screw of Steel pipe plug the grounding cable and remove the Steel pipe Check whether the quartz tube is damaged or not 6 R...

Page 13: ...After replacing the heater test the following parameters 8 Calibrate the temperature refer to Soldering temperature calibration 13 Troubleshooting No Error Message Fault Descriptions 1 H E Indicates t...

Page 14: ...12 14 Nozzles...

Page 15: ...le List Nozzle A1124 A1130 A1300 Heater A1147 220V Steel pipe 857 Mica paper 857 74x18mm ceramic packing Handle 857 Holder 957D The handle sheath Fuse 3A 5x20mm 40003228 Pump components Fan module 959...

Page 16: ......

Reviews: