USER MANUAL
10
NOTE: After
set
password, the temperature cannot be modify, enter
into parameter setting interface with new right password.
2.7.
Calibrating the temperature
Every time after replacing heating
components, to realign the outlet
temperature. Adopts digital temperature
calibration method, revised as key presses,
easy and quick adjustment.
Calibrate by using thermometer:
1. Set the unit’s temperature to a certain value.
2. When the temperature stabilizes, measure the tip’s temperature with
thermometer (QK196) and write down the reading.
3. Press “T+” and “F+” button not loosen, the soldering station enters
into calibrating temperature mode and LCD display flash, press “T-” or
“F-” key change temperature value, fit with thermometer reading, press
CH affirm.
* Suggest 196 temperature tester measure the outlet temperature.
* Must enter the correct password can only be calibrated.