background image

~ 7 ~ 

Window Messages 

The connection is not correct. Please check: 

Power

Cable

Baud Rate

The whole firmware update procedure fails. Please check 

Power

Cable

Baud Rate

The firmware update procedure requires a power cycle. 

Please turn off the device, wait for a couple of seconds, and power on 

the device. 

Congratulations. The whole process is successfully completed! 

Summary of Contents for 1B-SDI-PTGM2-HD

Page 1: ...3G HD SD SDI Monitor User Manual...

Page 2: ...ze the risk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation...

Page 3: ...SDI applications such as SDI video editing and HD surveillance system The handy SDI monitoring includes CRC status SMTPE 352M indicator audio bars EDH video format detection and Sync status etc With v...

Page 4: ...38kHz HDMI connector HDMI type A RS 232 connector DE 9 9 pin D sub female BNC connector 75 inter locked socket DIP switch Restore default Mechanical Housing Metal enclosure Dimensions L x W x H Model...

Page 5: ...put type and time Auto No use in this model C C No use in this model HDMI No use in this model Aspect Aspect ratio change TV No use in this model CV1 CVBS CV2 No use in this model YUV1 No use in this...

Page 6: ...ch Mode setting 3 RS 232 Serial control Rear Panel 4 SDI BNC loop out connectors SDI loop outs 5 SDI BNC input connector Input SDI CVBS 6 Power LED Indicate power up and signal lock 7 HDMI HDMI loop o...

Page 7: ...t or move the center of zoomed video to right or down 16 Display Display mode selection 17 Status SDI status indicator 18 Source SDI CVBS selection 19 Reset Reset error flags of SDI status indicator B...

Page 8: ...rk normally Software Interface Default Setting Firmware Update Pr ocedure ComPort Settings Select ComPort of PC connected to the device Push auto scan to start the automatic scan on each ComPort 1024...

Page 9: ...d Rate The whole firmware update procedure fails Please check Power Cable Baud Rate The firmware update procedure requires a power cycle Please turn off the device wait for a couple of seconds and pow...

Page 10: ...80x720 50Hz HDTV 720p 1280x720 59 94Hz HDTV 720p 1280x720 60Hz HDTV 1080i 1920x540 50Hz HDTV 1080i 1920x540 59 94Hz HDTV 1080i 1920x540 60Hz HDTV 1080p 1920x1080 25Hz HDTV 1080p 1920x1080 30Hz 3G 1080...

Page 11: ...log Dialog 2 SDI SYNC information EDH Status Frame CRC error Active picture CRC error General error 1 General error 2 SYNC Status SAV error SAV 3G error EAV error EAV 3G error SMTPE 352M Bytes Dialog...

Page 12: ...ntact with them might be fatal 6 Overloading Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock 7 Object and Liquid Entry Never push objects of any...