![Quest Engineering PowerHeat 980 Pro CHH-980 Installation, Operation And Maintenance Instructions Download Page 23](http://html1.mh-extra.com/html/quest-engineering/powerheat-980-pro-chh-980/powerheat-980-pro-chh-980_installation-operation-and-maintenance-instructions_772447023.webp)
1-866-413-5214
Quest Oil Fired CHH-980 Installation, Operation and Maintenance Instructions
23
quest
quest
www.QuestProtect.com
6.2 Maintenance Frequency Chart
Start of Every Start of Heating
As
Project
Season
Necessary
User Performed Tasks:
Check pressure & temperature gauges for "Normal Function Lev els" during operation
√
√
√
Check Aquastat for "Correct Setpoint" during operation
√
√
√
Check LED lights for "Correct Function" during operation
√
√
√
Check Fuel Gauge and order a deliv ery if necessary ( Propane sy stems only )
√
√
√
Check HTF Lev el Gauge and add HTF if necessary
√
√
√
√
If HTF loss is ex cessiv e, Check all Hoses & accessories for Leaks and Repair
√
Clean Y-strainer's Screens
√
√
√
Ex amine all hoses and replace or repair any that are cracked or in any w ay damaged
√
√
√
Lubricate all quick couplers w ith light oil
√
√
Thoroughly Clean the sy stem inside and out
√
√
Ex amine The Flue gas ex haust pipe and Rain cap. Clean as needed
√
√
√
Check condensate drainage tube and clean if necessary
√
√
√
Make certain that no flammable materials are any w here near the heating unit
√
√
√
√
Make certain that nothing is allow ed to obstruct the combustion air intake louv ers
√
√
√
√
To be Performed by Trained Service Technician
Perform a Flue Gas Analy sis test (using instruments) to confirm clean combustion
√
√
√
Test Ignition Safety Shutoff dev ice on burner
√
√
√
Test Low Water Cut-off Safety sw itch
√
√
√
Test High Temperature Limit sw itches
√
√
√
Test High Pressure Limit (blocked flue) sw itch
√
√
√
Check flue gas passagew ay s for soot or any ty pe of blockage and clean if necessary
√
√
MAINTAINENCE TASKS
Daily